Equipment: recreational vehicle/trailerReported July 15, 2008 · 70,101 vehicles affected
What is wrong
Fleetwood is recalling 70,101 my 2003-2007 southwind, pace arrow, bounder, flair, storm, fiesta, terra gas class a motor homes; bounder, discovery, providence, excursion, expedition, revolution, american eagle, american heritage, american tradition diesel class a motor homes; jamboree tioga class c motor homes; and prowler, wilderness, terry, mallard, pioneer, pride and triumph conventional and fifth wheel travel trailers equipped with a two-door refrigerators manufactured by the dometic corporation. The refrigerator may have a defect in the boiler tube. Pressurized coolant solution could be released into an area where an ignition source (gas flame) is present.
Risk
If this solution is exposed to an ignition source under certain specific circumstances, it can result in a vehicle fire.
Remedy
Fleetwood is working with dometic to repair these refrigerators (please see 08e032). Dometic will repair these refrigerators by installing a secondary burn housing, a thermal fuse, and a melt fuse free of charge. Dometic has retained stericycle inc. To manage this campaign. Stericycle will assist the owner in locating dealerships or service centers and will provide assistance with scheduling of appointments. Owners may contact dometic/stericycle at 1‑888‑446‑5157 or fleetwood at 1‑800‑322‑8216.

Recall number 08V320000 · Recall details

Equipment: other: labelsReported August 10, 2007 · 56 vehicles affected
What is wrong
Certain travel trailers fail to comply with the requirements of part 567, "certification." the information provided on the certification and tire information labels denoting the tire pressure is incorrect.
Risk
Driving with under-inflated tires can cause or contribute to premature tire failure that could result in a loss of control of the vehicle, increasing the risk of a crash.
Remedy
Owners will be sent correct federal certification and trailer weight information tags and installation instructions. An owner can have these tags installed at their dealership if they do not want to install the tags themselves. The recall began on august 15, 2007. Owners may contact fleetwood at 1‑800‑445‑3307.

Recall number 07V352000 · Recall details

Equipment: recreational vehicle/trailerReported March 19, 2007 · 167,096 vehicles affected
What is wrong
Certain motor homes and travel trailers equipped with a two-door refrigerator, manufactured by the dometic corporation, may have a defect in the boiler tube. Pressurized coolant solution could be released into an area where an ignition source (gas flame) is present.
Risk
Release of coolant under certain conditions could ignite and result in a fire.
Remedy
Fleetwood will be working with dometic in order to repair these refrigerators (please see 06e076). Dometic will repair these refrigerators by installing a secondary burn housing, a thermal fuse, and a melt fuse free of charge. Dometic has retained stericycle inc. To manage this campaign. Stericycle will assist you in locating dealerships or service centers and will provide assistance with scheduling of appointments. Owners may contact dometic/stericycle at 1‑888‑446‑5157 or fleetwood at 1‑800‑322‑8216.

Recall number 07V120000 · Recall details

Wheels: lugs/nuts/bolts/studsReported February 28, 2006 · 21 vehicles affected
What is wrong
Certain conventional and fifth wheel travel trailers may have been equipped with improperly hardened axle wheel studs.
Risk
Improperly tightened wheel studs may break at any time, causing the wheel and tire assembly to separate from the trailer, resulting in a loss of vehicle control and result in personal injury or a vehicle crash.
Remedy
Dealers will inspect and replace the trailer hub and drum assemblies free of charge. The recall began on march 29, 2005. Owners may contact fleetwood at 800‑455‑3307.

Recall number 06V060000 · Recall details

Power train: axle assemblyReported January 18, 2006 · 14 vehicles affected
What is wrong
On certain travel trailers, the axle width is too narrow causing the tires to rub on the inside of the wheel well housing.
Risk
This can cause the tires to fatigue and prematurely fail, which could result in a crash.
Remedy
Dealers will inspect and change the axle free of charge. The manufacturer has telephoned all dealers and owners concerning this recall. A followup letter will be sent during january or february 2006. Owners may contact fleetwood at 1‑800‑322‑8216.

Recall number 06V012000 · Recall details

Equipment: other: labelsReported November 7, 2005 · 48 vehicles affected
What is wrong
Certain travel trailers fail to conform to the requirements of federal motor vehicle safety standard no. 120 "tire selection and rims for motor vehicles other than passenger cars." the tire and loading information placard contains incorrect "load range "b" information regarding the maximum cargo carrying capacity. The correct tire is a load range "c".
Risk
A fully loaded travel trailer will overload the tires, which could lead to tire failure, loss of vehicle control, and could result in a crash.
Remedy
Dealers will inspect and replace tires that are marked "load range "b" and replace it with a "load range "c" tire. The recall began on november 30, 2005. Owners may contact fleetwood at 1‑800‑445‑3307.

Recall number 05V511000 · Recall details

Equipment: recreational vehicle/trailer: lpg systems: lines and fittingsReported September 27, 2005 · 180 vehicles affected
What is wrong
On certain fifth wheel trailers, the propane gas lines that run through the floor of the slide out room penetrate the floor too far from the outside wall causing the potential for pinched lines during slide out room operation.
Risk
This could lead to a propane gas leak and the potential for an explosion and/or fire.
Remedy
Dealers will inspect and, as necessary, reroute the propane gas line. This recall began on october 24, 2005. Owners may contact fleetwood at 1‑800‑509‑3418.

Recall number 05V433000 · Recall details

StructureReported June 21, 2005 · 496 vehicles affected
What is wrong
Certain fifth wheel travel trailers have missing welds on the chassis cross-members.
Risk
This condition can cause the cross-member to become dislodged, creating a road hazard if the fifth wheel travel trailer is in motion, which could result in a crash.
Remedy
Lippert components, in conjunction with fleetwood, will inspect the cross-members for missing welds, repair the welds if necessary, and add additional support to the affected area. Owners may contact lippert directly at 1‑866‑524‑7821 to make arrangements to have this inspection and repair performed. The recall began on august 4, 2005.

Recall number 05V289000 · Recall details

WheelsReported June 28, 2004 · 3,426 vehicles affected
What is wrong
On certain fifth wheel and conventional travel trailers equipped with aluminum wheels may not have had the proper wheel lug nut torque applied. Additionally, paint applied to the mating surface of the hub may cause the lug nuts to be more sensitive to loosening during the initial settling-in of components and after a wheel has been removed for service.
Risk
A wheel separation could occur, increasing the risk of a crash.
Remedy
Dealers will inspect, repair, or replace any damaged wheels, lug nuts, lug studs, and mating surfaces. Dealers will also remove paint film from the mating surfaces. The recall began on august 5, 2004. Owners should contact fleetwood at 1‑800‑509‑3418.

Recall number 04V310000 · Recall details

Electrical system: wiring: fuses and circuit breakersReported March 22, 2004 · 765 vehicles affected
What is wrong
On certain conventional and fifth wheel travel trailers equipped with siemens q circuit breaker, the circuit breakers were mis-marked.
Risk
This could result in an overheated conductor in a sustained overload condition which could cause personal injury and/or property damage.
Remedy
Dealers will inspect and replace the circuit breaker if necessary. Owner notification is expected to begin by april 5, 2004. Owners should contact fleetwood at 1‑800‑322‑8216.

Recall number 04V145000 · Recall details

Equipment: recreational vehicle/trailerReported November 4, 2003 · 60,877 vehicles affected
What is wrong
On certain travel trailers equipped with samsung microwave ovens, these ovens were produced with a defective panel. An electrical short can occur between circuit patterns on the membrane panel, especially overlapped by a "jumper" or jump wire. This may cause the oven to activate without pressing any key pads.
Risk
An electrical short can occur causing the oven to activate without pressing any key pads. This could result in excessive heat, smoke, or possibly a fire.
Remedy
Samsung will notify customers and repair the panel free of charge. In the meantime, consumers should unplug their microwave, if possible. If the consumer is unable to unplug the microwave, they should leave the door ajar until the panel is replaced. Consumers should never use the microwave oven for storage or leave any towels, paper, cloth or other products in the microwave after use. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact samsung at 800‑932‑3837 or fleetwood at 1‑800‑629‑8454.

Recall number 03V452000 · Recall details

WheelsReported November 4, 2003 · 4,933 vehicles affected
What is wrong
On certain conventional and fifth wheel travel trailers, the owner manuals either do not contain the wheel lug nut torque information or contain incorrect wheel lug nut torque information for the optional "aluminum wheel"
Risk
Vehicle operation without the proper torque applied to the wheel lug nuts could result in the lug nuts becoming loose and a wheel separation that could result in a crash.
Remedy
Owners will be provided with a label and insert to be added to the owner's manual. If the vehicle has the "aluminum wheel" option, owners are requested to bring their vehicle into a dealer to have the wheel lug nuts torqued to the proper specifications. Owner notification began november 26, 2003. Owners should contact fleetwood at 1‑800‑445‑3307.

Recall number 03V437000 · Recall details

Electrical system: 12v/24v/48v battery: cablesReported August 12, 1998 · 735 vehicles affected
What is wrong
Vehicle description: travel trailers (only models 26a and 24b are affected, and further identified by the characters "7a26" or "7b24" in the fourth through seventh positions of the vehicle identification number. The main wiring harness and generator battery wiring could be damaged by the generator exhaust system.
Risk
This condition could cause melting of the wiring insulation, creating an electrical short. This could lead to a fire.
Remedy
Dealers will relocate and secure the battery cable and main wiring harness away from the generator exhaust system; install a heat shield to protect wiring from excessive heat exposure from the generator exhaust; and replace any damaged wiring, if necessary.

Recall number 98V191000 · Recall details

Electrical system: wiringReported April 12, 1995 · 365 vehicles affected
What is wrong
The wiring to the breakaway switch located on the park trailer a-frame was incorrectly installed. This switch activates the trailer brakes if the park trailer becomes disconnected from the tow vehicle during towing.
Risk
If the park trailer were to become disconnected during towing, the trailer brakes would not be activated increasing the potential fora vehicle accident.
Remedy
Owners will be supplied with a kit and instructions to correct the wiring of this switch. If owners prefer, their dealer can perform the rewiring of the switch for them without charge.

Recall number 95V078000 · Recall details

Equipment: recreational vehicle/trailerReported March 22, 1994 · 142 vehicles affected
What is wrong
The stoves installed in the travel trailers were manufactured for natural gas operation and were not converted to propane gas operation. Use of a natural gas stove with propane gas fuel will create a high level of carbon monoxide.
Risk
High carbon monoxide levels in the travel trailer interior can result in asphyxiation of the occupants.
Remedy
Dealers will convert the stoves for propane gas by making adjustments where necessary.

Recall number 94V050000 · Recall details

Electrical system: wiring: fuses and circuit breakersReported August 1, 1990 · 575 vehicles affected
What is wrong
Miswired ground fault interrupter (gfi) receptacle in bathroom does not provide ground fault protection at that receptacle.
Risk
The miswired bathroom receptacle would not protect userfrom an electrical shock situation that could be avoided by a properly groundedground fault receptacle.
Remedy
Authorized dealers will correctly rewire the ground fault interrupter receptacle for proper fault protection.

Recall number 90V141000 · Recall details

Questions about the Fleetwood Terry recalls

How do I check if my Fleetwood Terry has an open recall?

Enter your VIN in the VIN decoder on this page to see the recalls for your exact model and year, then confirm with any dealer of the brand or the manufacturer, who can tell you whether the repair was already done on your car.

Do I have to pay for a recall repair?

No. Safety recall repairs are free at any authorized dealer of the brand, even if the car is out of warranty or you are not the first owner.

How many recalls does the Fleetwood Terry have?

16, covering equipment, wheels and power train.

VIN decoder

See the problems and recalls for an exact car

Buying a used Fleetwood Terry?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history