Check a VIN

2010 Gillig Low Floor recalls

There are 9 safety recalls on record for the 2010 Gillig Low Floor, covering 59,952 vehicles in total across all the models in each campaign. Newest first.

All recalls

Exterior lighting: turn signalReported June 20, 2018 · 25,579 vehicles affected
What is wrong
Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Risk
The reduced visibility of the turn signals can increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1‑510‑264‑5073 or 1‑800‑735‑1500.

Recall number 18V418000 · Recall details

Exterior lighting: turn signalReported February 24, 2017 · 17,056 vehicles affected
What is wrong
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
Risk
The reduced visibility of the turn signals may increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1‑510‑264‑5073 or 1‑800‑735‑1500.

Recall number 17V119000 · Recall details

SeatsReported January 13, 2016 · 6,734 vehicles affected
What is wrong
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.
Risk
If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.
Remedy
Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1‑800‑735‑1500.

Recall number 16V011000 · Recall details

Electrical system: wiring: front underhoodReported July 1, 2015 · 6,971 vehicles affected
What is wrong
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.
Risk
If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.
Remedy
Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners may contact Gillig customer service at 1‑800‑735‑1500.

Recall number 15V420000 · Recall details

Engine and engine cooling: engineReported May 5, 2015 · 1,101 vehicles affected
What is wrong
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.
Risk
If engine oil comes into contact with a hot surface, there is an increased risk of a fire.
Remedy
Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 2, 2015. Owners may contact Gillig customer service at 1‑800‑735‑1500.

Recall number 15V262000 · Recall details

Engine and engine cooling: engineReported June 23, 2014 · 648 vehicles affected
What is wrong
Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Risk
If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Remedy
Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1‑800‑735‑1500.

Recall number 14V358000 · Recall details

Engine and engine cooling: engineReported February 27, 2014 · 643 vehicles affected
What is wrong
Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.
Risk
The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.
Remedy
Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1‑510‑785‑1500 or Cummins Inc. at 1‑800‑343‑7357.

Recall number 14V084000 · Recall details

Visibility: glass, side/rearReported October 18, 2012 · 657 vehicles affected
What is wrong
Gillig is recalling certain model year 2010 Lowfloor transit buses, manufactured April 16, 2010, through November 16, 2010, and equipped with Ricon 3-Minute Urban Transit Bus Window sets. The composition of the material used to cast the handle that opens the egress window is incorrect, resulting in a reduction in material strength. The handle(s) on the emergency egress passenger windows may break before the window latch is released.
Risk
In the event the egress window handle fails during an actual emergency situation, passengers may be trapped in the vehicle placing them at risk of injury.
Remedy
Gillig will notify owners, and dealers will replace the window handles free of charge. The recall began during October 2012. Owners may contact Gillig at 1‑800‑735‑1500 for more information.

Recall number 12V506000 · Recall details

Engine and engine coolingReported August 10, 2011 · 563 vehicles affected
What is wrong
Gillig is recalling certain model year 2010-2011 lowfloor buses equipped with cummins engines. The v-band clamp assembly used to connect the inlet and outlet cone sections to the diesel oxidation catalyst (doc) diesel particulate filter (dpf) include a t-bolt which can fracture and fail when subjected to stress or load. A fracture or failure of the t-bolt may cause the clamp to loosen and the inlet or outlet sections attached to the doc/dpf housing to disconnect.
Risk
If the inlet or outlet sections disconnect, hot exhaust gases can vent prior to exiting the tailpipe, creating the risk of combustion and a fire. If both clamps fail, there is a risk in some applications that the doc/dpf housing may detach completely, creating a road hazard.
Remedy
Gillig is working with cummins to identify owners. Cummins is handling the owner notification and remedy for this campaign please see the federal safety agency recall 11e-031. Owners may contact cummins at 1‑812‑377‑5000.

Recall number 11V411000 · Recall details

Questions about the 2010 Gillig Low Floor recalls

How do I check if my 2010 Gillig Low Floor has an open recall?

Enter your VIN in the VIN decoder on this page to see the recalls for your exact model and year, then confirm with any dealer of the brand or the manufacturer, who can tell you whether the repair was already done on your car.

Do I have to pay for a recall repair?

No. Safety recall repairs are free at any authorized dealer of the brand, even if the car is out of warranty or you are not the first owner.

How many recalls does the 2010 Gillig Low Floor have?

9, covering exterior lighting, seats and electrical system.

VIN decoder

See the problems and recalls for an exact car

Buying a used 2010 Gillig Low Floor?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history