Equipment adaptive/mobilityReported September 26, 2014 · 828 vehicles affected
What is wrong
Forest River, Inc. (Forest River) is recalling certain model year 2006-2014 Glaval Universal, Primetime, Sport, Titan, and Titan II transit and shuttle buses manufactured January 1, 2006, to September 26, 2014, and equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon. The platform side plate of the affected wheelchair lifts may crack.
Risk
If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.
Remedy
Forest River will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on December 1, 2014. Owners may contact Glaval customer service at 1‑800‑445‑2825 or Ricon customer service at 1‑800‑322‑2884.

Recall number 14V599000 · Recall details

Equipment adaptive/mobilityReported April 30, 2014 · 42 vehicles affected
What is wrong
Glaval Bus (Glaval) is recalling certain model year 2007-2012 Universal, Primetime, Sport, Concorde, Titan, Titan II, Entourage and Apollo transit buses manufactured January 1, 2007, through December 3, 2012, and equipped with certain Ricon S-series and K-series wheelchair lifts, with an optional armored pendant cable. The armored cable may be positioned such that it does not clear the wheelchair lift.
Risk
If the cable does not clear the wheel chair lift it may contact the power lug and if it does not have a nonconductive cover, or it has an improperly installed non-conductive cover, then a short circuit may occur that could result in a fire.
Remedy
Glaval will notify owners, and Ricon will send owners a supplemental cover kit and instructions, free of charge. The recall is expected to begin in June 2014. Owners may contact Glaval customer service at 1‑800‑445‑2824 or Ricon Customer Service at 1‑800‑322‑2884 or by e-mail at [email protected].

Recall number 14V226000 · Recall details

Electrical system: alternator/generator/regulatorReported January 8, 2014 · 467 vehicles affected
What is wrong
Glaval Bus is recalling certain model year 2010-2013 Universal, Entourage, Concorde II, Titan, Titan II and Legacy transit buses manufactured June 1, 2010, through June 30, 2013, and equipped with a Ford 5.4L or 6.8L engine and a Trans/Air-brand air conditioner. In the affected vehicles, depending on the routing of the alternator harness, and the orientation of the heater hose spring clamp at the front of the intake manifold, the alternator harness may be pinched between the spring clamp and the air conditioner compressor mounting bracket.
Risk
The charging system may fail which could lead to the vehicle stalling while driving, increasing the risk of a crash. Additionally, the spring clamp could pierce both the positive and negative wires of the alternator harness creating a short circuit which could result in a fire.
Remedy
Glaval Bus will notify owners, and Trans/Air dealers will inspect the vehicles, correct the clamp installation and repair and reroute the alternator harness, as needed, free of charge. The recall began on January 22, 2014. Customers may contact Glaval at 1‑574‑262‑2212.

Recall number 14V004000 · Recall details

EquipmentReported July 15, 2013 · 3,705 vehicles affected
What is wrong
Glaval Bus is recalling certain model year 2010-2013 Universal, Concorde II, Entourage, Primetime, Titan II, Apollo, and Sport buses, certain model year 2011-2013 Titan II lf and Legacy buses and certain model year 2010 Synergy buses. The affected buses are equipped with a rear interior air conditioner evaporator which may come loose from its ceiling mounting over time.
Risk
The evaporator unit may detach from the ceiling and fall increasing the risk of injury.
Remedy
Glaval will notify owners, and dealers will tighten and replace the air conditioner evaporator mounting bolts, as needed, free of charge. The recall began on July 8, 2013. Owners may contact Glaval at 1‑800‑445‑2825 or [email protected].

Recall number 13V309000 · Recall details

EquipmentReported December 10, 2012 · 704 vehicles affected
What is wrong
Glaval Bus is recalling certain model year 2007-2012 transit buses, models: Entourage, Sport, Universal, Titan, Titan II, Apollo, Primetime, and Concord; and manufactured January 1, 2007, through December 3, 2012. The buses are equipped with a Ricon manufactured wheelchair lift which has an optional armored pendant cable. The cable may have been installed such that it doesn't clear the wheelchair lift and without a protective cover, or a misinstalled protective cover.
Risk
The cable may contact the power lug at the base of the wheel chair lift causing a short circuit that could result in a fire.
Remedy
Glaval Bus will notify owners and direct them to contact Ricon. Ricon will provide a supplemental cover kit and instructions, free of charge. The recall campaign began on January 23, 2013. Owners may contact Glaval Bus at 1‑574‑262‑2212 or Ricon at 1‑818‑267‑3000.

Recall number 12V580000 · Recall details

Structure: body: roof and pillarsReported August 3, 2012 · 90 vehicles affected
What is wrong
Glaval Bus is recalling certain model year 2011-2012 transit buses equipped with Speciality Manufacturing Inc. (SMI) ProLo roof escape hatches. Increased friction between the rear plate assemblies, p/no. 009327, and the nylon rear pop-up support, p/no. 008956, may result in opening force of the ProLo roof hatches that exceeds Federal standard requirements. Thus, these hatches fail to conform to the requirements of Federal Motor Vehicle Safety Standard No. 217, "Bus Emergency Exits and Window Retention and Release."
Risk
In the event of an emergency, passengers' exit from the bus may be hindered, possibly resulting in injury to the vehicle occupants.
Remedy
Glaval Bus will notify owners. SMI will provide service kits along with repair instructions to dealers and owners, free of charge. The safety recall began on August 17, 2012. Owners may contact Glaval Bus at 1‑574‑262‑2212 or SMI at 1‑800‑951‑7867.

Recall number 12V384000 · Recall details

Equipment adaptive/mobilityReported July 9, 2012 · 381 vehicles affected
What is wrong
Glaval is recalling certain buses equipped with braun century-2 and/or vista-2 wheelchair lifts. Over time and with frequent use, the roll stop latches on the outer barrier may become bent or misaligned.
Risk
A wheelchair occupant may defeat or ride over the insufficiently latched roll stop. If this occurs when the lift platform is in an elevated position, the wheelchair’s occupant could fall and sustain injury.
Remedy
Glaval will notify owners, and the repairs will be performed by authorized braun dealers free of charge. Owners may contact glaval bus at 1‑800‑347‑7440.

Recall number 12V321000 · Recall details

Equipment: appliance: air conditionerReported January 13, 2012 · 1,407 vehicles affected
What is wrong
Glaval is recalling certain model year 2006 through 2007 transit buses built on ford, gmc, chevrolet, and freightliner chassis and equipped with carrier genv em-1 evaporator units. Due to time, temperature, and/or vibration, the fuse may loosen in the fuse holder resulting in high resistance and arcing.
Risk
If sufficient arcing occurs, the fuse holder may melt, and a vehicle fire may occur.
Remedy
Glaval will notify owners and provide information on how to obtain the retrofit kit from carrier along with repair instructions. This service will be performed free of charge. The safety recall began on january 14, 2012. (see carrier's recall campaign 11e-003.) owners may contact carrier at 1‑800‑348‑7440.

Recall number 12V011000 · Recall details

EquipmentReported August 2, 2011 · 39 vehicles affected
What is wrong
Glaval bus is recalling certain model year 2010 and 2011 titan ii and universal transit buses manufactured from april 1, 2010, through july 1, 2011. One of the fire suppression discharge nozzles was incorrectly placed in the driver's station.
Risk
In the event of a system discharge, a significant cloud of powder could be released into the driver's compartment possibly obstructing the driver's view. This situation could result in a vehicle crash.
Remedy
Glaval bus will notify owners and the buses will be repaired free of charge. The safety recall began on august 30, 2011. Owners should contact getaway marketing, inc. At 1‑941‑747‑5486 ext. 221 or glaval bus at 1‑800‑445‑2825.

Recall number 11V402000 · Recall details

See all 9 recalls for the 2011 Glaval Universal

Used buying checklistWhat to check on a 2011 Glaval Universal before you buy

Compare the 2011 Glaval Universal

Other model years

2004

Questions about the 2011 Glaval Universal

Is the 2011 Glaval Universal reliable?

Owners have filed 0 complaints about the 2011 Glaval Universal.

What is the most common problem with the 2011 Glaval Universal?

There are not enough complaints to tell.

How many recalls does the 2011 Glaval Universal have?

9 recalls, covering equipment adaptive/mobility, electrical system and equipment.

Share your experience with the 2011 Glaval Universal

Tell other buyers what went wrong and what it cost. We review every report before it appears, and we never publish names, emails or VINs.

No names, contact details or links. Reports about a dealer or a person are not published.

VIN decoder

See the problems and recalls for an exact car

Buying a used 2011 Glaval Universal?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history
Is this car on a recall?Check VIN