Check a VIN

2016-2019 Horton Type I and Horton Type III recall: electrical

Halcore Group, Inc. reported this safety recall on March 4, 2020. It covers about 18 vehicles.

vehicles affected
18
reported
Mar 4, 2020
owners notified
Mar 10, 2020

Equipment: electrical

What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Emergency Vehicles Type I and Type III ambulances. The A/C input power cord for the Sensata inverter may be undersized for certain inverter applications, possibly resulting in an electrical short circuit.
Risk
An electrical short circuit increases the risk of a fire or a shock hazard.
Remedy
Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 20V128000

Affected vehicles

Questions about recall 20V128000

Is there a recall on the 2016-2019 Horton Type I and Horton Type III electrical?

Yes. Recall 20V128000, reported on March 4, 2020, covers about 18 vehicles.

What is the fix for recall 20V128000?

Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Is the recall repair free?

Safety recall repairs are done free of charge at authorized dealers. A dealer can confirm with the VIN whether a specific vehicle is included and whether the repair has already been done.

VIN decoder

See the problems and recalls for an exact car

Buying a used Horton Type I?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.