Electrical system: wiring
Van Hool technical service bulletin SB1402 for 2008-2017 Van Hool TD925 and 2015-2018 Van Hool TDX25.
- Bulletin number
- SB1402
- Component
- Electrical system: wiring
- Summary
- Van Hool has determined that the parcel-rack lighting circuit is not well executed due to an error in the production process. On TD925 vehicles, a connection in the parcel-rack lighting circuit is inadequate. The splicing of the electrical wires has been executed by twisting the strands together and insulating them with electrical tape instead of using a connector. Also neighbouring spare wires were mistakenly put together in the same connection. This situation can result in arching and overheating when the parcel-rack lighting circuit is energized and one of the spare wire ends is grounded. Follow the step-by-step instructions mentioned under "To modify TD925 parcel-rack lighting c ircuit". The necessary parts are listed in the table on page 2. On TDX25US vehicles, a 4-pin connector with loose wires has not been removed as it should have been. This may result in arching and overheating when the parcel-rack lighting circuit is energized and one of the loose wire ends is grounded. Follow the instructions mentioned under ?To modify TDX25 parcel-rack lighting circuit?. No parts are necessary for TDX25 vehicles.
Vehicles covered
VIN decoder
See the problems and recalls for an exact car
Buying a used Van Hool TD925?
Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.