Check a VIN

February 8, 2018 Service bulletin

Due to an error in the Cooltech AC system Data Panel condenser fan controller firmware regarding freon...

Horton Ambulance technical service bulletin HTB2018-01.18 for 2013-2017 Horton Ambulance 453, 2013-2017 Horton Ambulance 457 and 2013-2016 Horton Ambulance 503 and others.

Bulletin number
HTB2018-01.18
Component
Equipment: appliance: air conditioner
Summary
Due to an error in the Cooltech AC system Data Panel condenser fan controller firmware regarding freon sensor fault points, there is a possibility that below freezing temperatures could cause false AC system fault warning messages. Recommending vehicles fitted with Data Panel fan controllers built prior to 01/15/2018 and having firmware revision 010E or earlier, update Data Panel controller firmware revision to Rev F (015). There is no safety concern related to this bulletin, Ac system will continue normal operation if fault is displayed. All Models fitted with Data Panel CoolTech AC system condenser fan controller.

Vehicles covered

VIN decoder

See the problems and recalls for an exact car

Buying a used Horton Ambulance 453?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history