Delivery stop: safety battery terminal control line
MINI technical service bulletin M610120 for 2020 MINI Cooper S.
- Bulletin number
- M610120
- Component
- Electrical system
- Summary
- DELIVERY STOP: SAFETY BATTERY TERMINAL CONTROL LINE This Service Information Bulletin (Revision 1) replaces SI B61 01 20 dated February 2020. If the vehicle and the ignition is turned off after 10 - 15 min the high voltage components will switch off and the engine cannot be re-started a red Check Control Message will be displayed. The power supply / control line for the safety battery terminal SBK is connected to wrong terminal connector.
Owners of these vehicles have filed 1 complaints in the electrical category.