The battery merge solenoid may not connect to charge both banks of batteries, resulting in a NO START...
Entegra technical service bulletin TSB 20-019 for 2019 Entegra Anthem and 2019 Entegra Cornerstone.
- Bulletin number
- TSB 20-019
- Component
- Electrical system: wiring: relays/solenoids
- Summary
- The battery merge solenoid may not connect to charge both banks of batteries, resulting in a NO START situation. An inspection is required to confirm the color of the existing solenoid. White or Grey notes the solenoid is correct and not further action is required, while finding a BLACK solenoid notes a new is required to prevent a NO START situation.
Vehicles covered
- Entegra Anthem 2019 2019
- Entegra Cornerstone 2019 2019