Check a VIN

December 10, 2020 Service bulletin

Altec has discovered that the fuse for the main contactor in the L JEMS system on the affected units can...

Altec technical service bulletin SIL 777 for 2007 Altec AT40M/P and 2019 Altec LR760.

Bulletin number
SIL 777
Component
Electrical system
Summary
Altec has discovered that the fuse for the main contactor in the L JEMS system on the affected units can be undersized. A 250 amp fuse may have been installed instead of the required 400 amp fuse. This can cause repeated blowing of the fuse and resulting loss of power. Altec has created a service kit to replace the fuse and connecting cable. This will prevent improper blowing of the fuse and ensure that the cable is properly sized. Altec requires that the kit be installed no later than the next regular maintenance interval.

Vehicles covered

VIN decoder

See the problems and recalls for an exact car

Buying a used Altec AT40M/P?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.