Auto gen start cycles the generator off after being started for the air conditioner after only 10 minutes...
Triple E technical service bulletin CA#9970 for 2021 Triple E Unity, 2020 Serenity S24CB and 2020 Unity U24CB and others.
- Bulletin number
- CA#9970
- Component
- Electrical system
- Summary
- Auto gen start cycles the generator off after being started for the air conditioner after only 10 minutes instead of the intended HVAC temperature setting being reached. Design error, the shore power sense module of the ec-30 controller is located after the transfer switch so the setting for the sp sense should have been after instead of before.
Vehicles covered
- Triple E Unity 2021 2021
- Serenity S24CB 2020 2020
- Unity U24CB 2020 2020
- Unity U24FX 2020 2020
- Unity U24IB 2020 2020
- Unity U24MB 2020 2020
- Unity U24TB 2020 2020
VIN decoder