Fuel pump assembly had a malfunction in the check valve where the fuel in one tank would empty into the second tank. This problem caused an overflow of fuel which would then spill out of the fuel tank. There is a recall #93v125000, but this vehicle is not covered under the recall due to VIN. *ak
1992 Ford F-150 fuel system complaints
Page 3 of 9: complaints 41 to 70 of 245, newest first, as owners wrote them.
Vehicle has problem with gas frequently pumping from the back fuel tank to the front tank. *mr this often happened when the front tank was full and gas would expelled from the front gas tank. The consumer's was told that the VIN did not match with the recall. *scc
Dealer performed ford recall 93s68 twice on my vehicle which did not correct problem. Fuel crossflow still occurred from rear tank to front tank resulting in a hazardous condition that the recall was meant to correct. Returned truck to ford dealer for a third time to correct the same problem. I was charged $602.90 to replace front fuel pump. This should have been covered under the recall, because the original recall did not alleviate the hazardous condition.
Per manufacturer's system recall 01i008000 for the fuel duel tank leakage was performed. Consumer never received a recall letter, so vehicle was never taken into dealership to have recall done. Defect has now occurred, but vehicle is now over the mileage indicated in the recall. *ak
The vehicles recall related to the check valve in the fuel pump failed.
The vehicle experienced problems with the fuel system. The consumer stated that there was a recall issued which was never received and that now when they took the vehicle in for the recall they were over 6000 miles over the limit for the recall. Dealer and manufacturer were not contacted at the time of this call.
The vehicle has dual tank the front tank empty into the second tank and spilling out of the gasoline tank. Please provide additional information dealer is aware of the problem. Ts
Consumer states fuel is being transfered from rear to forward tank and is spewing out because pressure is higher than what tank can handle. Related recall 01f105000, but consumer's v.I.n. Is not included. Ts
Uel is being transferred from rear tank to front tank without vehicle being engaged. Consumer had vehicle repaired twice under safety campaign. This condition cause gas to leak out of tank while driving. Consumer was informed that because fuel is transferring when vehicle is not engaged, once vehicle is driven and fuel transfer is initiated front tank is overflowing.
Received recall 01i008000; fuel would come out of the front tank while driving. Also owner can smell fumes inside the cab of the truck. Problem happens whether fuel tank is full or when weather is hot. Owner has taken truck to dealership twice. He was informed that check valve was not part of recall, and refuse to do recall repairs. Please describe details.
Consumer's vehicle was having the same problem with fuel leakage as stated in recall 01 f 105 000. But dealership refused to fix it, warranty expired, and they did not know how to fix it.*ak consumer stated that when the back tank was pushing fuel through the front tank, the front fuel tank was leaking. Took the vehicle to the dealer to fix but, the problem still exist.
This defect was the subject of the federal safety agency recall campaign id # 011008000. The corrective summary in the recall notice states the dealer is to "repair the condition free of charge." however, the dealer charged me some $500 for the repair, which seemd to defeat the purpose of the recall.
the federal safety agency CAMPAIGN NUMBER 011008000 CROSS TANK FUEL FLOW - DUAL TANKS.
Two fuel pumps have gone out while consumer was driving and at the time. Consumer lost power. Contacted dealer. *ak
Consumer discovered gasoline leaking from the rear dual tank, when the gas tank was opened, gas shot out over 5 inches across the parking lot, the gas tank was replaced, however several days later the problem reoccured, when vehicle was taken into dealer, consumer learned of a recall that affected his make, model and year, however he was informed that his VIN was not included in the recall even though he had experienced that exact symptom.
Consumer will fill in information concerning fuel tank leak.
Fuel system returns fuel from the rear tank to the front tank causing an overflow problem. The front tank becomes pressurized and leaks fuel onto the ground. The fuel system on this truck is a safety hazard, and has been recalled twice. The first recall fixed the problem temporarly but the fuel system failed again. My truck was out of warranty and since the recall was already preformed I was told I would have to pay for any repairs. Recently a second recall came out from ford (recall #01m05h). When I tried to have my problem fixed the dealership told me that the recall does not cover the problem I am having with my truck. The recall work preformed replaced a regulator assembly and fuel tube connection, but I was told my fuel pump is bad and that is what is causing the overfilling of the front tank. It would cost almost $500.00 to repair my fuel system. How many problems are there with the ford fuel system?
Consumer was calling dealer in regard to recall #01i008000 concerning fuel tank cross flow. But, dealer has been unable to have repairs done due to lack of parts, and rutsy bolts. Please provide further details.
In october of 1999 a private repair shop replaced front fuel tank pump correcting a fuel tank crossover problem. However, problem has reoccurred, and fuel pump sender assembly was faulty. Dealer could not remedy the problem. *ak the gas from rear tank empties into the front tank causing gas to spill. The consumer had it fixed, but the problem reoccurd and the consumer received recall notice and the dealer replaced the fuel regulator instead of the pump and problem still not solved.
Consumer received recall (93s68) and made an appointment for the necessary repairs, however when consumer went to drop off the vehicle, he was then informed that the parts were not available , and if there were was no gas leaking from vehicle not to worry about it, consumer went to another dealer and was also told there were no parts available and not to worry.
This is the first and only recall we have been notified on this vehicle. We need to know if there are any other recalls of which we have not been notified.
93s68 recall performed in 1993, fuel tank malfunction same as described in recall...out of pocket expense $789.83 unable to obtain refund from dealer.
Recall 93 v 125 000/fuel tank assembly: unused fuel from one tank to be returned to the second tank, when this occurs second tank exceeded, causing fuel spillages. Spill can result in a fire when exposed to a source of ignition. Dealer was notified, and infomed consumer that vehicle was not covered under recall due to VIN. Feel free to provide any further details on this matter.
Ea99-032; fuel is being pumped from front tank to rear tank, causing fuel spillage. Cause is unknown.
Fuel is being transferred from one tank to another while vehicle is in operation. Consumer took vehicle to dealership that informed consumer that repair work for recall 93v125000 had previoud no record of taking vehicle in for this problem. Please provide any additional information/attachments.
This vehicle is experiencing same defect as described in the federal safety agency recall campaign 93v125000. However, dealership informed consumer that this vehicle was not included in recall due to VIN.
Consumer's vehicle isn't part of recall 93v125000/ manufacturer's recall 93s68 although it has same problem as stated in recall. Consumer has dual tanks, and modules between allow gas to go to back which causes fuel to overflow. Consumer is second owner, and dealer is denying recall repairs due to VIN.
Consumer was traveling 45mph on highway and another vehicle flagged him down that he was leaking fuel from underneath vehicle.
Consumer had contacted dealer in reference to recalls 94 v 169 000 and 93 v 125 000. Consumer believed recall work was not done correctly as fuel tank was leaking. Dealer bob bell ford 7125 richie hwy. Glen burnie, md. 410‑766‑3600. *ak the dealer failed to remove the leaking fuel tank, and the consumer stated that the problem was dangerous unless action was taken.
After filling up fuel tank fuel gauge will show on dashboard that tank is empty.