Check a VIN

1997 Ford Ranger fuel system complaints

Page 2 of 3: complaints 11 to 40 of 67, newest first, as owners wrote them.

See the summary of 1997 Ford Ranger fuel system problems: which part fails, at what mileage and related recalls.

Filed Aug 1, 2011 · Fuel system · 105,000 miles · IL

Fuel tank straps failed due to corrosion/rust causing fuel tank to partially fall. Defective straps were replaced with new ones.

Filed May 10, 2011 · Fuel system · 113,900 miles · IL

Within the past two months I had a split in the flexible fuel filler pipe on my 1997 ford ranger xlt. In the course of having it replaced, the repair shop removed the gas tank and found the same condition with the metal straps that hold the gas tank in place, extensive corrosion as reported on the ford f150. It appears the possibility of gas tanks dropping out of the vehicle may be more extensive than the initial reports and may apply to other ford pick-up trucks.

Filed Mar 1, 2011 · Fuel system · 84,000 miles · FL

Fuel line cracked above gas tank . Strong gas odor after driving or during refill -gas will spill out when filling tank up to full and gas smell can also be smelled during commute. Will be taking it in to greenway ford dealership here in orlando this week.

Filed Sep 22, 2010 · Fuel system · 72,000 miles · TX

Tl* the contact owns a 1997 ford ranger. The contact stated that when the vehicle is filled with gasoline, the gas will spill back out. The contact took the vehicle to the dealer and was told that the bottle neck on the filler cap is corroded. This causes a strong smell of gas when driving the vehicle. The dealer was very familiar with the failure, but the vehicle is no longer under warranty all and there is no recall. The failure mileage was 72000 and current mileage was 75000.

Filed Aug 16, 2010 · Fuel system · 125,000 miles · MD

Crack in gasoline filler top causing fumes and gasoline odor in car, especially when turning right. * when filling tank with gasoline, the fuel would leak out of the filler neck onto the ground while filling at the gas station, as if you were slowly pouring a glass of water, much more than a drip. Could not fill tank full until repair was done. Mechanic replaced filler and filler neck. Had to remove gas tank and truck bed to investigate and repair. Big job, big hazard!!

Filed Aug 5, 2010 · Fuel system · 180,000 miles · OR

Fuel leaking around filler top. First time service replaced the hose clamp, but now the filler top is cracked. Oem replacement part is $500 plus labor of removing gas tank , etc. Odor a problem and potentially a fire hazard. Gas stations do not want to put gas in leaking vehicle either.

Filed Jun 14, 2010 · Fuel system · 90,000 miles · OR

1997 ford ranger xlt ,date is approximate since filler hose slowly cracked and got worse, smelled fuel constantly since 80,000 miles and had to eventually spend 600.00 to get it fixed at ford dealership for what looked like a small rubber hose, I would have replaced myself but could not locate oem replacement anywhere else including all auto stores (dealer only part), this was a very dangerous situation, I considered it a timebomb. Thankfully nothing dangerous happened before I took it to dealer, though doing a internet search revealed a common problem for the certain years of ford rangers which some people due to cost are replacing with a common rubber hose which is very dangerous and has static that could make it go up in flames.

Filed May 10, 2010 · Electrical, Engine · 70,000 miles · MD

Electrical problems: 1. Intermittent wipers will wipe 2, 3, 4, 5 times at random in a row always and not in that order. 2. Backup lights continue to blow fuse after replacing all lighting parts 3. Horn works 1% of the time, unable to find cause. 4. Ac blows hot air intermittently even after replacement of blower blend door. 5. Gas: when below 1/4 tank and making right turn truck will stall, even after work on tank.

Filed Apr 20, 2010 · Brakes, Driver assistance · 1,500 miles · CA

I own a 1997 ford ranger xlt 4x4 4.0ltr.many shops have work on the front axel wheel bearings and seals and retainer nut this nut takes a socket 2.3/8 r-6 most shops don't have it so they use what ever they have,chisell,locking plyers ect...creating front end damage to wheel bearings,seals, brakes,calipers,brake drums, most of al the tires..I have spent thousands of dollars because they did not use the right tool for the job also did not remove lcking pin from spindel.

Filed Apr 14, 2010 · Fuel system · 150,000 miles · TX

When filling fuel tank on 1997 ford ranger 4x4 long bed, fuel leaks back out and puddles on pavement below vehicle due to a split that has recently developed in the fuel tank filler neck (hose). Even when I do not fill tank all the way (to prevent above leaking) gas fumes are still strong and have accumulated inside the canopy (topper) on pickup bed. Fuel appears to leak (based on odor) after executing a sharp turn, a quick stop, and when traveling over bumpy roads. Ford's price for a replacement filler neck is prohibitive (around $450) plus labor and thus, I have been unable to have the problem repaired.

Filed Mar 10, 2010 · Fuel system · 76,414 miles · TX

The gasoline hose from the filler cap to the tank is cracking. This is a common problem, as seen on ranger web forums. This causes gasoline to leak from the hose as the tank fills. The fuel spills on the ground or very near the catalytic converter. The entire scenario could cause a major fire incident. Additionally, this hose cracking occurred years ago when the vehicle was newer, but not reported until now. This cracking should not occur and could cause serious damage if gas fumes were to ignite. The cracking occurs mostly at the corner where the hose enters the gasoline tank. It is virtually impossible to repair without major costs due to its location.

Filed Dec 14, 2009 · Fuel system · 195,000 miles · PA

Fuel filler hose cracks prematurely at the connection to the top of the fuel tank resulting in significant fuel spillage during refueling as well as probably splashing out during driving. Fuel vapors surely escape all the time as well. Both situations lead to a serious fire hazard. Seems to be a widespread safety issue based on the amount of ford rangers with safety complaints listed on this site as well as discussions on various ford ranger forums. The oem ford part lists for ~$400.

Filed Oct 15, 2009 · Fuel system · 130,000 miles · GA

Fuel filler tube cracks at the fuel pump, resulting in fuel pouring out and fuel vapors escaping while driving or while parked. This could result in the vehicle catching on fire. *tr ford is aware of the problem and sells replacement filler tubes for upwards of $500, not including labor.

Filed Jun 16, 2009 · Fuel system · 106,000 miles · MD

1997 ford splash ranger short bed truck leaking gasoline from the fuel filler hose where it connects to the fuel tank. The hose is cracked but not rotten and fuel leaks on the ground when filling the tank and also when the tank is near full. Definite fire hazard.

Filed May 16, 2009 · Fuel system · 95,000 miles · MI

1997 ford ranger xlt short bed truck leaking gasoline from the fuel filler hose where it connects to the fuel tank. The hose was cracked but not rotten and fuel would leak while filling the tank and also when the tank was near full, but always had fuel vapors escaping. A fire hazard and excessive hydro carbon emissions.

Filed Mar 13, 2009 · Fuel system · 141,000 miles · AR

Tl*the contact owns a 1997 ford ranger. The contact smelled a strong odor of gasoline emanating from his vehicle and noticed gasoline leaking from the fuel tank. A fire could erupt in the presence of an ignition source. He took the vehicle to his local mechanic and had the filler hose replaced. The manufacturer would not assume responsibility for the failure because the vehicle exceeded its warranty. The failure mileage was 141,000 and current mileage was 142,000.

Filed Dec 26, 2008 · Fuel system · 139,609 miles · GA

Tl*the contact owns a 1997 ford ranger. The contact stated that both the inner and outer hoses cracked and caused a significant amount of fuel to spill out from the top of the fuel tank when it is filled. The dealer was notified and they stated that it would cost $600 to repair. The manufacturer stated that they could not assist with the repairs because the vehicle was not under warranty. The failure mileage was 139,609 and current mileage was 139,839. Updated 2/9/09 *cn the dealer replaced the fule filter. Updated 02/13/09. *jb updated 07/20/09 *bf updated address. 07/21/09.

Filed May 13, 2008 · Fuel system · 100,000 miles · TX

Tl*the contact's sister owns a 1997 ford ranger. The contact stated that whenever fuel is placed into the vehicle, the fuel leaks out on two sides. The vehicle was taken to a dealer and they stated that the fuel overflow was cracked and needed to be replaced. The current mileage was 144,819 and failure mileage was 100,000.

Filed May 12, 2008 · Fuel system · FL

The fuel filler hose has a hole in it, therefore when you fill up your vehicle; gas leaks out onto the ground. I was not aware of a problem until I was fueling one day and I ended up with a puddle on the ground. This is not only a fire hazard, but also an environmental one too.

Filed May 9, 2008 · Fuel system · 110,000 miles · FL

Fuel filler hose. The hoses (both inner & outer crack and cause a significant amount of fuel to spill out from the top of the fuel tank if fuel tank is filled. The hose is an expensive part to replace. I was told by the local ford dealership that this part is one of the most popular parts they sell." (the part costs between $225.00 and $500.00) plus labor.

Filed May 5, 2008 · Fuel system · FL

This complaint is in reference to a 1997 ford ranger and fuel filler hose being faulty. The hose itself has cracks in it and leaks fuel upon refill presenting a fire hazard as well as an environmental hazard due to the fuel vapors that are allowed to escape to the environment due to the cracks in faulty fuel filler hose. This is a potential fire hazard and an environmental protection agency issue. Please put forth an effort to correct problem before fire, injuries, and , potential deaths are sustained, issue a recall.

Filed Feb 1, 2008 · Fuel system · TX

The fuel filler hose on my mother-in-laws 1997 ford ranger developed numerous cracks where it attaches to the tank. This problem results in gasoline spills whenever she completely fills the tank. The tank is in close proximity to the exhaust system which creates a fire hazard. This problem seems to be common with 1990-1997 rangers, according to numerous online posts.

Filed Jan 16, 2008 · Fuel system · 96,000 miles · FL

Tl*the contact owns a 1997 ford ranger. The contact experienced a major fuel leak and smelled a strange odor in the passenger compartment. Two independent mechanics confirmed that there was a failed fuel filler tube. The mechanics also stated that he would have to pay $800 to have the fuel filler tube replaced. The contact stated that fuel leaks from the fuel tank every time he adds fuel to the vehicle. The failure has occurred ever since the vehicle was purchased and has since become progressively worse. The manufacturer stated that there were no recalls on his vehicle and the failure was his responsibility. The contact is concerned that a fire may occur at any time. He has photos if needed. The vehicle does not have cruise control. The failure mileage was 96,000 and current mileage was 97,479.

Filed Aug 10, 2007 · Fuel system · IN

Noted fuel running onto the ground while refueling vehicle. Investigation revealed that a rubber portion of the fuel filler assembly near the entrance to the fuel tank had split. Contacted local ford dealership. They offered to order a replacement fuel filler assembly but did not offer any other assistance despite the obvious safety issue involved. Part cost exceeds $400. Estimated labor is ~$200. Note: this same problem is documented by others. See complaint numbers 10151411, 870010 & 10110378. I did not search the database for other model years but there is sufficient anecdotal evidence to indicate that this has been an extremely widespread problem with both ford ranger and mazda b-series vehicles for several model years.

Filed Mar 27, 2007 · Fuel system · 68,000 miles · NH

Fuel filler tube cracked where it enters the fuel tank, allowing fuel to leak when filling up.

Filed Dec 18, 2006 · Fuel system · 75,242 miles · IL

Tl*- the fuel leaks when the vehicle is completely refueled. The problem stems from the fuel filler assembly. The dealer said that the parts for the vehicle were not available. The contact was told he needed to bring the vehicle in to be looked at, and would be charged an $80 fee. The contact feels that this a safety issue and that the $80 fee is appropriate.

Filed Nov 22, 2006 · Fuel system · 23,000 miles · CA

1997 ford ranger. Whenever I fill up with gas, it leaks out the vent or the filler tube. Not exactly sure yet. If I push the fuel nozzle all the way in the filler I can get almost a full tank before it leaks out the bottom. If I just install the filler hose and let it fill automatically it will start leaking almost immediately.

Filed Nov 8, 2006 · Fuel system · 120,000 miles · CA

Dt*: the contact stated while parked in the driveway a puddle of gas was noticed under the vehicle and an odor of gas was present inside the vehicle. It was driven to an independent repair shop who determined the filler pipe was cracked and needed to be replaced. The dealer was alerted.

Filed Oct 17, 2006 · Fuel system · 2,000 miles · IL

Fuel filler hose cracked leading to large amount of fuel spillage. Part is not available separately from dealer and no aftermarket parts are available. Assembly to replace part consisted of parts that were unnecessary to the proper repair.

Filed Oct 9, 2006 · Fuel system · 50,000 miles · LA

During fueling of vehicle a strong smell of gas was occurring at each fueling. I first noticed what appeared to be moisture under the truck and being in a high temp/humidity environment thought it was AC condensation. Recently while not running the AC noticed the leakage and crawled under the truck and smell the liquid. It was gas. I am very concerned since the leak is very close to the exhaust system and as well as being an environmental (epa) hazard. It is amazing the ECM module fuel evaporative emission sensor does not detect the defect in the closed loop emission system and set an emission error fault code. I would like to know how many gallons of fuel leaked due to this conditions. It is important we have 'no ozone action days' where refueling is restricted but allow known defects. An investigation should be conducted to determine which ford models /years used this less than robust fuel supply connection systems. If a proper design fmea and sha (safety hazard analysis) were conducted for the fuel supply tube and its mating connections. This condition should reported for a recall for the potential safety, emissions issues (health,ozone) and determine why the ECM does not detect a evaporative emissions leak condition.

VIN decoder

See the problems and recalls for an exact car

Buying a used 1997 Ford Ranger?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history