Check a VIN

Horton Type I recalls

There are 8 safety recalls on record for the Horton Type I, covering 1,214 vehicles in total across all the models in each campaign. Newest first.

Horton Type I recalls by model year

2026 12025 12020 32019 52018 62017 32016 2

All recalls

Equipment: emergency: fire supressionReported August 14, 2026 · 545 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2025-2026 Horton Type I, Type III, and Critical Care ambulances. The touchscreen display may stop responding to touch commands or fail to power on, preventing the activation of exterior emergency lights, as well as fire fighting and other emergency equipment.
Risk
A loss of exterior lights can reduce the visibility of the vehicle to other drivers, increasing the risk of a crash. Inoperative equipment can delay emergency response, increasing the risk of injury.
Remedy
Weldon Division of Akron will update the firmware and repair the power line, free of charge. Owner notification letters are expected to be mailed October 5, 2026. Owners may contact Weldon customer service at 1‑800‑228‑1161 or Halcore customer service at 1‑800‑447‑0343.

Recall number 26V533000 · Recall details

Electrical systemReported December 1, 2020 · 251 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2020 Horton Emergency Vehicles Type I and III and ambulances equipped with Weldon i4G Vivtech Displays. The processor that runs the display may stop functioning without warning, causing items operated through the control panel to not function.
Risk
If the control panel stops functioning, a delay in emergency services may occur, increasing the risk of injury.
Remedy
Halcore will notify owners, and dealers will inspect and repair the i4G Vivtech rear and/or front display within the serial number range, free of charge. The recall began December 8, 2020. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 20V745000 · Recall details

Service brakesReported May 20, 2020 · 17 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Emergency Vehicles (HEV) Type I & Type III ambulances built on a Ram 4500 or 5500 chassis and equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.), part numbers DS135RS3A, DS135RS3AF, DS135RS3-DM. The rear brake caliper flexible line may have been routed so that it contacts a suspension component, possibly causing excessive wear and a loss of rear brakes. The affected system component is the rear brake caliper flexible line which may be causing brake caliper to wear due to contact suspension components.
Risk
A worn rear brake caliper flexible line may cause brake fluid leakage which may result in a partial or complete loss of the rear brakes, increasing the risk of a crash.
Remedy
Halcore will notify owners, and dealers will inspect the rear brake caliper flexible lines for wear and install a kit to modify the rear brake caliper flexible line mounting, and if necessary, a kit to replace worn brake lines, free of charge. This recall began June 5, 2020. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 20V291000 · Recall details

Equipment: electricalReported March 4, 2020 · 18 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Emergency Vehicles Type I and Type III ambulances. The A/C input power cord for the Sensata inverter may be undersized for certain inverter applications, possibly resulting in an electrical short circuit.
Risk
An electrical short circuit increases the risk of a fire or a shock hazard.
Remedy
Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 20V128000 · Recall details

EquipmentReported October 17, 2019 · 11 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2018-2019 Horton Type I & Type III ambulances. The D-cylinder oxygen tank bracket may loosen, allowing the oxygen tank to separate and become airborne in the event of a crash.
Risk
An unsecured oxygen tank may strike ambulance occupants and increasing the risk of injury in the event of a crash.
Remedy
Halcore will notify owners, and Ziamatic will refund the purchase price paid, or provide replacement bracket assemblies, free of charge. The recall began November 7, 2019. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 19V742000 · Recall details

Air bagsReported August 19, 2019 · 80 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Type I and Type III Emergency vehicles. Due to improper manufacturing, the cushion of the Inflatable Head Cushion (IHC) and Knee Air Bag (KAB) may detach during a deployment event and not inflate.
Risk
In the event of a crash, if the cushions do not inflate properly, they may not provide the intended protection to the occupant, increasing the risk of injury.
Remedy
Halcore will notify owners and dealers will install replacement air bags when they become available, free of charge. Halcore issued owners an interim notification on September 6, 2019. The recall began September 20, 2019. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 19V608000 · Recall details

Back over prevention: sensing system: cameraReported April 9, 2019 · 49 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Type I and Type III ambulances equipped with ASA Electronics back-up camera displays. The displays may revert back to the factory default settings which may cause the camera image to be reversed.
Risk
The driver may inadvertently turn the wrong direction to avoid an object behind the vehicle, increasing the risk of a crash.
Remedy
Horton will notify owners and dealers will add a harness relay capacitor module to prevent the image from reversing, free of charge. The recall began June 13, 2019. Owners may contact ASA customer service at 1‑800‑384‑4400 or Halcore at 1‑800‑447‑0343.

Recall number 19V281000 · Recall details

Exterior lighting: brake lightsReported September 11, 2018 · 243 vehicles affected
What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2017-2018 Horton Type I and Type III ambulances, equipped with Whelen accessory brake lights. Depending on the specific wiring of the vehicle, these brake lights may illuminate when the brake pedal has not been pressed. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Risk
If the brake lights incorrectly illuminate, it can confuse other drivers, possibly increasing the risk of a crash.
Remedy
Halcore will notify owners, and Whelen will replace the brake lights, free of charge. The recall began October 16, 2018. Owners may contact Halcore customer service at 1‑800‑447‑0343.

Recall number 18V605000 · Recall details

Questions about the Horton Type I recalls

How do I check if my Horton Type I has an open recall?

Enter your VIN in the VIN decoder on this page to see the recalls for your exact model and year, then confirm with any dealer of the brand or the manufacturer, who can tell you whether the repair was already done on your car.

Do I have to pay for a recall repair?

No. Safety recall repairs are free at any authorized dealer of the brand, even if the car is out of warranty or you are not the first owner.

How many recalls does the Horton Type I have?

8, covering equipment, electrical system and service brakes.

VIN decoder

See the problems and recalls for an exact car

Buying a used Horton Type I?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.