Engine and engine cooling: engine
- What is wrong
- Daimler trucks north america is recalling certain model year 2005 through 2012 freightliner m2, sterling acterra, 7500 & 8500, and thomas built hdx vehicles manufactured from june 23, 2004, through march 15, 2011, equipped with specific mbe900 epa04 and epa07 model engines. The intake air grid heater may short circuit and fail due to excessive internal temperatures.
- Risk
- A short circuited grid heater could result in a vehicle fire and injury to vehicle occupants.
- Remedy
- Daimler trucks will notify owners, and dealers will repair the vehicles free of charge. Repairs will be performed by detroit diesel corporation authorized repair facilities. The safety recall began on september 12, 2011. Owners may contact daimler trucks toll-free at 1‑800‑547‑0712. This recall is an expansion of a previous recall, campaign number 10v‑341.
Recall number 11V455000 · Recall details
Fuel system, other: delivery: hoses, lines/piping, and fittings
- What is wrong
- Daimler trucks north america (dtna) is recalling 24,650 school and non-school buses, motor home chassis, and trucks manufactured from march 9, 2004 through august 18, 2006, equipped with epa04 certified mbe900 engines, manufactured by detroit diesel between march 1, 2004, and july 31, 2006. The high pressure fuel lines and transfer tubes may fatigue and fracture.
- Risk
- A fractured fuel line may leak diesel fuel possibly resulting in a fire or fuel may be spilled on the road causing a slippery surface, possibly resulting in a vehicle crash.
- Remedy
- Detroit diesel will notify owners and the vehicles will be repaired with more robust lines and vibration dampers free of charge. Repairs will be performed by authorized detroit diesel distributorships. The recall began on march 9, 2009. Owners may contact detroit diesel 1‑313‑592‑3708 or dtna toll-free at 1‑800‑547‑0712 for more information.
Recall number 08V668000 · Recall details
Electrical system: wiring: fuses and circuit breakers
- What is wrong
- Daimler trucks is recalling 18,198 my 2003-2009 thomas built er, mvp-er, hdx, and mvp-ef school and transit buses equipped with a dual power switch and manufactured from february 1, 2002 through october 17, 2008. Solid state circuit breakers may trip unnecessarily potentially resulting in a loss of power to the bus chassis and body electrical circuits causing an unexpected loss of engine power and exterior lighting.
- Risk
- Unexpected loss of engine power and exterior lighting could result in a vehicle crash.
- Remedy
- Thomas built bus dealers will replace the solid state dual power switch with a mechanical circuit production (mega fuse). The recall is expected to begin during april 2009. Owners may contact thomas built at 1‑336‑889‑4871.
Recall number 08V622000 · Recall details
Structure: body: door: hinge and attachments
- What is wrong
- Daimler trucks is recalling 243,435 my 1995-2008 thomas built school buses manufactured between january 1994, and march 10, 2008. (additional buses have been added to this recall campaign. Please see supplemental report no. 4) the emergency exit door handle begins corroding around the securing roll pin and square drive mechanism causing the protective finish to chip and flake. Continued corrosion and pitting weakens the handle. Handles weakened by corrosion may break while trying to open the door from the exterior.
- Risk
- In the event of an emergency, a person on the outside of the bus may break the door handle trying to open the emergency exit potentially delaying evacuation and increasing the risk of personal injury to the vehicle's occupants.
- Remedy
- Daimler trucks will notify owners and will replace the handles with a more robust handle free of charge. Repairs will be performed by thomas built buses dealerships. The recall began on august 18, 2008, and notification for the revised population is expected to begin on or about april 29, 2009. Owners may contact thomas built at 336‑889‑4871.
Recall number 08V087000 · Recall details
Equipment adaptive/mobility
- What is wrong
- Daimler trucks is recalling 760 my 2003-2007 thomas built school buses manufactured between july 6, 2005 and july 19, 2006, equipped with braun wheelchair lifts, models nl, ncl, or nvl. The threshold warning systems of the subject model wheelchair lifts fail to comply with the requirements of federal motor vehicle safety standard no. 403, platform lift systems for motor vehicles.
- Risk
- Should the threshold warning system fail to operate, the lift user can fall from the vehicle and be seriously injured.
- Remedy
- Daimler trucks will notify owners and provide a free remedy which will be performed by thomas built dealerships. The recall began on august 8, 2008. Owners may contact thomas built at 336‑889‑4871.
Recall number 08V088000 · Recall details
Electrical system: wiring: fuses and circuit breakers
- What is wrong
- Certain 2001 through 2008 thomas built fs-56, er, mvp er, hdx, and mvp ef school buses manufactured from october 23, 2000, through january 24, 2006, equipped with tyco pc board and type ii auto reset circuit breakers. Type ii auto reset circuit breaker temperatures may exceed the rating of the tyco pc board causing the boards to melt potentially resulting in a vehicle fire.
- Risk
- A vehicle fire can occur possibly resulting in a crash.
- Remedy
- Thomas built will notify owners and repair the buses by replacing the type ii auto reset circuit breakers with manual circuit breakers, and the jumper cable. The recall began on march 28, 2008. Owners may contact thomas built customer support office at 336‑889‑4871.
Recall number 07V544000 · Recall details
Equipment adaptive/mobility
- What is wrong
- Certain my 2004-2007 thomas built minotour, fs65, mvp-ef, and hdx model school buses, manufactured between june 16 and july 1, 2005, equipped with ricon wheelchair lifts. Cracks in the lift arms may allow the mechanism to twist during stowage, preventing closure of the safety interlock switches.
- Risk
- In the event this condition occurs during passenger operations it may not be possible to close the lift door causing the vehicle interlocks to remain engaged preventing movement of the vehicle or the ability to load or unload passengers with disabilities from the vehicle.
- Remedy
- Ricon is conducting this recall (please see 06e008000) and will replace the two vertical arms even if only one arm is cracked free of charge. The recall is expected to begin on may 30, 2006. Owners may contact ricon customer support dept. At 800‑322‑2884 or owners may contact thomas bus customer support office at 336‑889‑4871.
Recall number 06V150000 · Recall details
Electrical system: wiring: fuses and circuit breakers
- What is wrong
- Certain my 2004 through 2006 thomas built hdx, ef, and fs-65 school buses manufactured between october 4, 2004, and february 14, 2006. The body power distribution module (pdm) was manufactured with copper circuits that are too thin for the electrical loads encountered, possibly causing the board to overheat.
- Risk
- If the pdm overheats it may generate smoke and could result in a fire.
- Remedy
- Thomas built will notify owners and will replace the pdm's thin copper circuits with thicker copper circuits. The recall began on june 30, 2006. Owners may contact thomas built at 1‑877‑660‑4938.
Recall number 06V136000 · Recall details
See all 8 recalls for the 2005 Thomas Built Buses HDX
Defect investigations
Emergency door handle failure
The office of defects investigation opened this preliminary evaluationafterbecoming aware that fleets were having handle failures on the rear emergency door exit.the failure resulted in the door handle separating from thedoor latch mechanism.when the handle fails, the rear emergency exit door can not be opened from outside the bus.the failure results from corrosion of the exterior door handle around the securing roll pin and square drive latch mechanism, causing the protective finish to chip and flake.continued corrosion weakens the handle and eventually the handle may break while trying to open the exit door.odi was concerned that during an emergency, a person outside of the bus would break the door handle while trying to open the emergency exit door,potentially delaying evacuation of the bus.under the safety recall, the aluminum handles will be replaced with a more robust handle.the recall action resolves the issues raised by this investigation. Accordingly, this investigation is closed.
PE07054
Electrical panel fires
This investigation was opened based on four allegations of school bus fires in the power distribution module (pdm) area of the subject buses.during the investigation, odi learned thatbuses built between october 4, 2004 and february 14, 2006 were equipped with pdm?s manufactured with copper circuits that were too thin for the electrical loads encountered, creatingoverheating and thermal events.also, it was determined that multiple thermal breakers, clustered together on the pdm, together with heat generated from the pdm can generate enough heat to melt the pdm.on april 21, 2006, freightliner filed a safety recall to address this issue.freightliner's remedy is to replace all the original (thin copper circuit) pdm?s with new improved pdm?s having thicker copper circuits.also, freightliner will replace the thermal breakers with non-thermal breaker or fuses. The recall action taken by freightliner resolves the issues raised by this investigation.this investigation is closed.
PE06012
Technical service bulletins for the 2005 Thomas Built Buses HDX 83
Bulletins tell dealers how to fix known problems. A warranty extension means the manufacturer pays for that repair for longer.
- Thomas Built Buses Product Awareness Bulletin on Improved Through Lugg Compt Dr
- SS:1034175 tbb
- Service Bulletin Paper Copy Mailings Are Discontinued
- Service Information Bulletin- Oil Present at the Turbocharger Compressor Housing
- Service Solution: 1033968 TBB Warning Lights, One Side Flashes Faster than the Other
- 14CSA23 csc
- Service Solution SS 1033208TBB TM21 Dual AC alignment and not seate...
- 16-011
- 16TS7 Reman Diesel Particulate Filter Serial Number
- New Detroit Bearing Failure Analysis Standard Diagnostic Time
Compare the 2005 Thomas Built Buses HDX
Other model years
Questions about the 2005 Thomas Built Buses HDX
Is the 2005 Thomas Built Buses HDX reliable?
Owners have filed 0 complaints about the 2005 Thomas Built Buses HDX.
What is the most common problem with the 2005 Thomas Built Buses HDX?
There are not enough complaints to tell.
How many recalls does the 2005 Thomas Built Buses HDX have?
8 recalls, covering engine and engine cooling, fuel system, other and electrical system.