December 1, 2007 Service bulletin

Mini: electric cooling fan runs after engine is shut off

MINI technical service bulletin SIM-17-02-07 for 2001-2010 MINI Cooper and 2001-2010 MINI Cooper S.

Bulletin number
SIM-17-02-07
Component
Engine and engine cooling: cooling system: fan
Summary
Mini: electric cooling fan runs after engine is shut off. After the engine is shut off, the electric cooling fan continues to run. Due to the operating strategy of the dme, the electric cooling fan may continue to run after the engine is shut off in two different scenarios. Engine coolant temp reaches 108 degrees celsius (due to heat soak), cooling fan will activate til coolant temp drops below 105 degrees celsius. Fan will run to assist the auxiliary water pump, which is used to cool turbo charger after engine shut down. No model years listed.

Owners of these vehicles have filed 753 complaints in the engine category.

Vehicles covered

VIN decoder

See the problems and recalls for an exact car

Buying a used MINI Cooper?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history