When vehicle reaches speeds of 65 MPH and over fuel leaks from the tank. The dealer has not been able to duplicate the problem.
1993 Ford F-150 fuel system complaints
Page 10 of 11: complaints 251 to 280 of 287, newest first, as owners wrote them.
When duel tanks are filled gas pours out of the tank.
While driving the check valve within the fuel pump assembly caused a portion of the unused fuel from the tank to return to the second tank, causing fuel spillage. Owner contacted the manufacturer. Manufacturer said that the vehicle has been repaired under recall (93v‑125).
Fuel pump failed.
While driving vehicle about 30 MPH the when consumer filled up both fuel tanks, the rear tank overfilled and the front tank was like bleeding one to another, overflooding the front one. Consumer believed that happend because the check valve on the rear tank was not working correctly, and could cause a fire on the vehicle.
Fuel spilling from fill tube on front fuel tank, recall repairs refused due to VIN.
Filled up both tanks at a gas station and began driving down the road and switched the tank to the rear tank, and the gas began leaking out of the front tank. *akthe vehicle leaked about 6 gallons of fuel, a recall was issued but the consumer vehicle was not included due to VIN.
When driving the vehicle and runnig truck on the front fuel tank, the gas is overflowing into the rear fuel tank. Once the rear full tank gets full it spills gas out of the truck onto the street.
There was a recall issued but it was not on this vehicle, but this vehicle is having the same recall problem. Check vavle within the fuel pump assembly causes a portion of the unused fuel from one tank to be returned to the second tank. Owner has changed the fuel from the back to the front, but the fuel stills runs out on the ground. No either way trying to avoid using one of the tanks. Recall # 93v‑125 000.
While driving noticed the front gas tank pump gas into the back tank which caused the back tank to over flow/leaking gas into the street. This is a safety hazard. Dealer said that this vehicle does not comply with the recall for the fuel tank (93 v125 000).
Fuel spills over from front tank to rear tank, since front tank is larger that rear tank, when this happents all the fuel rear tank can't hold spills onto highway. Was repaired under recall, however didn't solve the problem.
Fuel moves from one tank to another, causing fuel to overflow through the filler cap.
The fuel pump failed, causing engine malfunction indicator light (mil) to activate.
When fuel system is selected to front gas tank, gas is pumped into the rear tank but not from rear to front.
Duel fuel tanks: when running on front tank, it pumps most of fuel into back tank, if back tank is full it causes fuel spillage; dealer replaced fuel pressure regulator, according to dealer, vehicle not included in recall #93v125000.
Fuel pump failed, causing fuel to spill out.
Fuel tank assembly: fuel pumps gas from rear to front tank. Vehicle is on recall, recall #93v125, but dealer won't repair vehice because vehicle was manufactured at end of dec. 1992.
The pump in the fuel tank is wearing out and needs to be replaced.
Vehicle fire.
When running off the rear fuel tank, fuel fills into the front fuel tank and when that tank is full the fuel spills onto the road. Dealer is aware of problem. Problem still exists.
Filler cap leaked prior to recall, recall repairs refused due to VIN.
Fuel is leaking from the fuel tank because when filling the vehicle with gas unused fuel is being returned to the second tank, causing fuel spillage consumer has taken the vehicle to the dealer under recall 93v125000.
Consumer is experiencing cross tank fuel flow.
A malfunctioning in the fuel pump is causing unused fuel in the back tank to flow to the front tank.
Purchased truck new, both fuel pumps failed . Please describe .
Both fuel pump systems have been replaced four times.*ak wiper switch failed. Air conditioner vent replaced.
The dealership did the recall repairs back in 1994 and the fuel tank is still feeding fuel into the front tank and then onto the ground.**ak ford will not repair, they stated that the recall work was only good for 12000 miles or 12 months.
Slave cylinder leak.
When front gas tank is used, stepping on the gas pedal causes truck to lurch/slow down, as if engine is flooding.
Portion of the unused fuel is spilling from the second gas tank recall #93v1250000, vehicle not included.
VIN decoder
See the problems and recalls for an exact car
Buying a used 1993 Ford F-150?
Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.
Check its history