Check a VIN

1993 Ford F-150 fuel system complaints

Page 9 of 11: complaints 221 to 250 of 287, newest first, as owners wrote them.

See the summary of 1993 Ford F-150 fuel system problems: which part fails, at what mileage and related recalls.

Filed May 14, 1999 · Fuel system · IL

A malfunctioning check valve within the fuel pump assembly causes a portion of unused fuel from one tank to be returned to the second, causing leakage. Vehicle not included in recall #93v125000. Please give any further details.

Filed Apr 15, 1999 · Fuel system · IL

Consumer is experiencing the same problem with fuel tank assembly as described in recall 93v125. Dealer has been contacted.

Filed Apr 6, 1999 · Fuel system · MN

The return fuel is going into the opposite tank, causing the fuel to overflow. Owner has contacted the manufacturerabout the problem. Owner was informed that his truck was not included in the recall. The problem has not been corrected. Please provide any further details.

Filed Mar 29, 1999 · Fuel system · IA

This vehicle is having the same problem as described in the recall with the two gas tanks where the second tank overloads and forces the gas back to the first tank. Dealer has been contacted. 93v‑125.

Filed Mar 25, 1999 · Fuel system · MN

There is a leakage coming from the gas tank. When consumer puts gas in one tank, the gas will transfer to the other tank, and the gas tank was already full which caused an overspill, recall on comp0nent, however vehicle not included due to VIN. .

Filed Mar 5, 1999 · Fuel system · NJ

Whenever using the front tank the gas will go straight to the second tank and cause an overspill.

Filed Mar 4, 1999 · Fuel system · MN

Fuel flows from one tank to the other and causes leakage and possible fire danger. I have moved since the purchase and the local dealer has informed me that this is about an $800 repair which would require the repacement of both fuel pump and or check valve. I have determined that there has been a recall issued for this vehicle and this problem but I was never notified. The nhsta campaign id# is 93v125000. Since this is a safety and pollution control problem it seems to me that the dealer should repair this problem at their cost. Your comments would be appreciated.

Filed Feb 3, 1999 · Fuel system · OH

Consumer experiencing ongoing problem with fuel backing out of the filler neck onto the street while driving.

Filed Jan 29, 1999 · Fuel system · MT

There is a malfunctioned check valve within the fuel pump which causes a portion of the unused fuel from the tank to be return to the second tank which causes a fuel spillage.

Filed Jan 27, 1999 · Fuel system · IA

Had pumped & filled fuel tank with gasoline. Can hear fuel entering other tank. When this happens the fuel would leak out & spill to the ground. Recall 93v125000.

Filed Jan 7, 1999 · Fuel system · IL

Vehicle has dual gas tanks, and one gas tank is overflowing with gas. Gas is squirting out as the vehicle is being driven. Dealer has seen.

Filed Jan 7, 1999 · Fuel system · CT

Vehicle was assembled with two tanks. Had the smell of gas around it. Consumer noticed gas leaking from out of the tank, and when the cap was removed gas started gushing out of the tank. Dealer was contacted. *ak

Filed Nov 23, 1998 · Fuel system · MO

The fuel from a dual fuel tank is filling up the other tank, causing the fuel to leak out of the vehicle. Owner cannot fill up the gas tank. Dealer says owner is not included in the recall for this problem.

Filed Nov 19, 1998 · Fuel system · MN

The consumer has been experiencing problems with fuel tank assembly. Fuel would spill out of vehicle at a rapid pace. The defects described are associated with recall number 93v125000. The manufacturer has been contacted.

Filed Nov 16, 1998 · Fuel system · PA

When driving at any speed the gas is leaking from the tank, and the consumer states he is losing fuel. Dealer can't determine the problem.

Filed Nov 13, 1998 · Fuel system · AZ

While putting gas into the vehicle the defective sensor in the gas tank caused a gas spillage when fueling. Cause unknown. Please provide further information.

Filed Nov 6, 1998 · Fuel system, Steering · ME

I was shifting my truck out of park and it snapped ,leaving me stuck.but, what would have happened if I was driving and needed to to put it in nuetral to slow quickly,and then it snapped? Also, just about every time I start it I have to step on the gas .is there a danger of it catching on fire from to much gas? Or just totally ruin my truck?

Filed Oct 29, 1998 · Fuel system · FL

Consumer states that the recall remedy did not correct the problem which allows fuel from the front tank to transfer to the second tank, resulting in leakage. Recall number 93v08900. Fuel leaks as soon as engine is turned on--tank will empty while driving in 4-5 minutes. *ak

Filed Oct 20, 1998 · Fuel system · ME

Fuel pump failed.

Filed Oct 16, 1998 · Fuel system · MD

A malfuctioned check valve within the fuel pump assembly, causes portion of unused fuel from one tank to be returned to second tank. When it occurs,the capacity of second tank can be exceeded,causing fuel spillage. Dealer notified and informed consumer this vehicle does not come under mfr. Recall. (the federal safety agency# 93v 125).

Filed Oct 13, 1998 · Fuel system · MA

Front fuel tank leaks due to a crack, cause unknown. Please give any further details.

Filed Oct 9, 1998 · Fuel system · MO

Fuel tank check valve within the fuel pump assembly failed resulting in leaking.

Filed Oct 2, 1998 · Fuel system · MD

Rear fuel tank takes fuel very slowly. Intermittently spits back at, causing a fuel spillage.

Filed Sep 6, 1998 · Fuel system · WI

Front tank fuel pump malfunctioned, causing fuel to leak.

Filed Jul 13, 1998 · Fuel system · LA

Onwer has dual gas tanks. When gas is filled gas overflows from one tank to the other. Excessive gas pressure.

Filed Jul 7, 1998 · Brakes, Fuel system · VA

Brakes failed several times.

Filed Jul 6, 1998 · Fuel system · CA

Fuel would go from one tank to another & then would spill out. This would happen when vehicle has been started.. Has happened at least 9 different times.

Filed Jun 3, 1998 · Fuel system · GA

A malfunction in the check valve within the fuel system, causes unused fuel to retuirn from one tank to the second, causing fuel spillage. Vehicle was not involved in the recall 93v125000.

Filed May 21, 1998 · Fuel system · TX

When filling both duel fuel tanks with fuel noticed fuel leakage under the vehicle. Also noticed the second tank fuel level was low, second tank was not being used.

Filed Apr 30, 1998 · Fuel system · AZ

Fuel switch control unit failed causing gas to leak out of vehicle.

VIN decoder

See the problems and recalls for an exact car

Buying a used 1993 Ford F-150?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history