Check a VIN

2000 Ford F-150 fuel system problems

152 complaints (14% of all complaints for this car). Typical mileage when it fails: 124,000. 1 crash reported.

owner complaints
152
of this car's complaints
14%
typical mileage
124,000
crashes
1
recalls
1

Which part fails

  • Storage: tank assembly: mounting
    17
  • Storage: tank assembly
    15
  • Storage: auxillary tank
    2
  • Delivery: hoses, lines/piping, and fittings
    2
  • Storage: tank assembly: filler pipe and cap
    1
  • Delivery: fuel pump
    1

At what mileage

Complaints by mileage at the time of the problem.

0k-25k
25k-50k
50k-75k
75k-100k
100k-125k
125k-150k
150k-175k
175k-200k
200k+

Ford F-150 fuel system problems in other years

19901995200020052010201520202025

Specific symptoms reported on the 2000 Ford F-150 fuel system

Phrases found in the owners' own descriptions, so one complaint can mention several symptoms.

Fuel leak 26Fuel smell 7

Related recalls

Fuel system, gasoline: storage: tank assembly: mountingReported July 29, 2011 · 1,100,000 vehicles affected
What is wrong
Ford is recalling certain 1997 through 2003 model year ford f-150, 2004 model year ford f-150 heritage, 1997 through 1999 model year f-250 less than 8,500 lbs. Gross vehicle weight rating (gvwr), and 2002 and 2003 lincoln blackwood vehicles manufactured from june 20, 1995, through august 4, 2004, originally sold, or currently registered in, connecticut, delaware, illinois, indiana, iowa, kentucky, maine, maryland, massachusetts, michigan, minnesota, missouri, new hampshire, new jersey, new york, ohio, pennsylvania, rhode island, vermont, west virginia, wisconsin, and the district of columbia. Prolonged exposure to road deicing chemicals may cause severe corrosion of the fuel tank straps which secure the tank to the vehicle.
Risk
As a result of the corrosion, one or both straps may fail allowing the fuel lines to separate from the tank, or in some cases, causing the tank to contact the ground. Either scenario may result in a fuel leak presenting a fire hazard.
Remedy
Ford will notify owners and instruct them to take their vehicles to a ford or lincoln dealer to have the fuel tank straps replaced with straps that have increased corrosion protection. Early in this campaign, if replacement straps are not available, dealers may install a cable support under the strap as an interim repair or a steel reinforcement over the existing strap as a permanent repair. Any repairs will be performed free of charge. The safety recall began on september 16, 2011. Owners may contact ford motor company customer relationship center at 1‑866‑436‑7332. Ford's recall campaign number is 11s21

Recall number 11V385000 · Recall details

Related investigations

Fuel Tank Strap Failure Due to CorrosionOpened May 4, 2011, closed August 19, 2011

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to the federal safety agency involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to the federal safety agency, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

EA11006

Fuel Tank Strap Corrosion/RustOpened September 7, 2010, closed May 23, 2011

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and break.If one strap breaks, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.This raises the possibility that the weight of the dropped tank could sufficiently strain the hoses and fittings to cause separation and fuel leaks between those components.The fire hazard created by the leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.The sparks could ignite the escaped fuel.ODI has included in its incident counts reports it has received from consumers and reports provided by Ford in which either the complaint involved confirmed strap corrosion or ODI's investigation yielded information that strongly suggests the subject defect as the cause of the reported problem.Among the incidents reported to the federal safety agency or Ford, 243 involved the fuel tank dropping below the vehicle and/or dragging on the ground, 95 involved fuel leakage, and nine included reports of sparks from the tank being dragged on the road.ODI has received one report of strap failure in which the leaking fuel ignited but self-extinguished.Ford reported another incident in which the leaking fuel ignited and the resultant fire destroyed the vehicle.There have been no injuries associated with these incidents.ODI has received reports of corrosion induced tank strap failures with other model year F-150 vehicles.ODI is upgrading this investigation to further investigate the frequency, severity and scope of this problem.

PE10036

What 2000 Ford F-150 owners say

Most recent owner complaints, unedited.

Filed May 21, 2025 · Engine, Fuel system · 142,000 miles · MN

The contact owns a 1991 Ford F-150. The contact stated that while attempting to accelerate from a complete stop, the vehicle was sluggish. The contact stated that the vehicle operated as needed after warming up. The contact stated upon refueling the vehicle, the gasoline would splash out of the fuel tank filler neck and onto the gas pump. There was no warning light illuminated. The local dealer was contacted, but the vehicle was not diagnosed or repaired. The manufacturer was notified of the failure. The approximate failure mileage was 142,000.

Filed Nov 16, 2020 · Fuel system · 207,000 miles · MO

Tl* the contact owns a 2000 ford f-150. The contact stated that the vehicle was taken to bill grant ford located at 3060 s springfield ave, bolivar, mo 65613, (417) 326-7671, where the vehicle was repaired under the federal safety agency campaign number: 11v385000 (fuel system, gasoline). While repairing the vehicle, the contact was informed that the fuel tank had a hole and needed to be replaced. The vehicle was not repaired. The manufacturer had been informed of failure. The failure mileage was approximately 207,000.

Filed Nov 15, 2016 · Fuel system · 202,000 miles · MA

Tl* the contact owns a 2000 ford f-150. While the vehicle was stationary, the fuel tank strap became detached from the fuel tank and caused the fuel tank to strike the skid plate of the vehicle. As a result, the fuel tank was fractured and caused fuel to spill out. The vehicle was not repaired. The manufacturer was made aware of the failure. The failure mileage was 202,000.

Filed Oct 27, 2016 · Fuel system · NE

Tl* the contact owns a 2000 ford f-150. While driving approximately 50 MPH, the fuel tank detached from the vehicle. The vehicle was towed to an independent mechanic where it was diagnosed that the straps and fuel tank needed to be replaced. The vehicle was repaired. The manufacturer was not made aware of the failure. The VIN and failure mileage were unknown.

Filed May 23, 2016 · Fuel system · 108,000 miles · NC

Tl* the contact owns a 2000 ford f-150. The contact stated that while the vehicle was parked, the fuel tank strap fractured and separated from the vehicle. The vehicle was not diagnosed or repaired. The vehicle was not included in the federal safety agency campaign number: 11v385000 (fuel system, gasoline). The manufacturer was notified of the failure. The approximate failure mileage was 108,000.

Filed Dec 17, 2015 · Engine, Fuel system · 172,000 miles · MI

While sitting stationary waiting for a traffic light. When the light changed I began to move and ejected a spark plug from my 5.4l triton engine. After hearing a loud popping noise and the cab of the vehicle filled up with gas fumes. Luckly I was close to home. But I am lucky that the engine compartment did not catch fire from gas and vapors in the engine area.

Filed Dec 10, 2015 · Fuel system · 140,000 miles · PA

Tl* the contact owns a 2000 ford f-150. The contact stated that there was a fuel odor coming from the vehicle. Upon further inspection, the contact noticed that the vehicle was leaking fuel from the undercarriage of the vehicle. The vehicle was taken to the dealer where it was diagnosed that the vehicle's fuel tank was rusted and fractured and needed to be replaced. The contact was also made aware of the federal safety agency campaign number: 11v385000 (fuel system, gasoline) in which the vehicle was included, but the contact failed to receive notification. The contact stated that the manufacturer would only cover the repair of the fuel tank straps and not the fuel tank itself. The vehicle was not repaired. The manufacturer was made aware of the failure. The failure mileage was 140,000.

Filed Feb 26, 2015 · Fuel system · 208,000 miles · AK

Having a fuel leak where the tank is strapped to the vehicle. Ford has a recall on this issue, but unfortunately not for my VIN number. I expect ford to make this right. It is too coincidental to have the same problem but not be covered for a recall. I cannot afford in any way the cost of the repairs for this problem. Please advise.

Filed Feb 24, 2015 · Fuel system · 203,000 miles · MI

Tl*the contact owns a 2000 ford f-150. The contact stated that there was excessive fuel leaking from the fuel tank. The failure occurred continuously. The vehicle was taken to a dealer where it was diagnosed that the fuel tank was damaged and needed to be replaced. The vehicle was not repaired. The manufacturer was not made aware of the failure. The failure mileage was approximately 203,000.

Filed Dec 16, 2014 · Fuel system · 114,000 miles · IN

Tl* the contact owns a 2000 ford f-150. The contact stated that while driving at approximately 45 MPH down a small hill, the fuel tank straps fractured and caused the fuel tank to dislodge from the vehicle. The vehicle was taken to the dealer who diagnosed that the fuel tank straps, the fuel tank, and the fuel pump needed to be replaced. The vehicle was not repaired. The manufacturer was notified of the failure. The failure mileage was 114,000.

Questions about the 2000 Ford F-150 fuel system

Does the 2000 Ford F-150 have fuel system problems?

Owners have filed 152 complaints about the fuel system of the 2000 Ford F-150, 14% of all its complaints.

At what mileage do 2000 Ford F-150 fuel system problems start?

The typical (median) mileage in owner complaints is 124,000 miles.

Was there a recall on the 2000 Ford F-150 fuel system?

Yes, 1 recall: 11V385000. Check your VIN to see if your car still needs the free repair.

What year does the Ford F-150 have the most fuel system problems?

The Ford F-150 model years with the most fuel system complaints are 1993 (287 complaints), 1997 (246 complaints) and 1992 (245 complaints).

Other 2000 Ford F-150 problems

Electrical 192Acceleration 188Engine 158Brakes 81Airbags 69Steering 68Body 66Transmission 47Suspension 41Tires 34Visibility 27Lights 23Seat belts 15Wheels 13Locks 7Seats 7Driver assistance 1

VIN decoder

See the problems and recalls for an exact car

Buying a used 2000 Ford F-150?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history