Bosch CP4 High Pressure Fuel Pump failed in transit cost $10,713 to repair only 155k miles on new engine. Diesel fuel spilled from engine on highway, lucky no fire. Ford no help.
Ford F-350 fuel pump problems
54 of the 2,894 owner complaints about the Ford F-350 describe fuel pump failure, most of them for the 2011 model year.
- owner complaints
- 54
- worst model year
- 2011
- typical repair cost reported
- $9,000
- typical mileage
- 72,000
By model year
Often reported together
Stalling 13Loss of power 6Check engine light 4Won't start 3Power steering loss 3Engine failure 3Fuel leak 2Tire blowout 1
Trouble codes mentioned
P0088 1
What owners say
The contact owns a 2011 Ford F-350. The contact stated while reversing, the vehicle failed to accelerate as intended while depressing the accelerator pedal. The contact stated that the vehicle stalled and failed to restart. There was no warning light illuminated. The contact stated that an independent mechanic arrived at the residence however, the vehicle failed to restart. The vehicle was towed to an independent mechanic. The contact was informed that the high-pressure fuel pump had failed, and the fuel system needed to be replaced. The vehicle was not repaired. The manufacturer was notified of the failure but denied assistance in covering the cost of the repair. The failure mileage was approximately 200,000.
Vehicle died while driving on the freeway. Towed to the local Ford who did a diagnostic and test they found that the engine is completely done with as there was an engine oil overfill, and it filled the CAC system and melted cylinder eight piston. they’re saying that they will need to replace the entire engine and HP fuel pump in order to repair and I see many others have experienced this same problem.
The fuel pump failed and self destructed internal parts of the pump in turn putting metal into the fuel lines resulting in a $15,000 repair bill. The vehicle is available for inspection and has not been repaired. This occurred in November 2024 and has not been driven since due to the costly repair bill. The problem has been confirmed by the dealership and independent service center. The only indication of the issue was when the check engine light illuminated. No other preemptive warning.
The contact owns a 2006 Ford F-350. The contact stated that while the vehicle was parked, the contact noticed that fuel was leaking underneath the front driver's side of the vehicle. The vehicle was taken to an independent mechanic, who replaced the fuel pump block-off plate and plug. The manufacturer was made aware of the failure and advised the contact to file a complaint with the federal safety agency Hotline. The failure mileage was approximately 190,000.
Summary: We purchased a brand new 60000 dollar truck in 2012 or 2013 and was assured by the dealer that it had a warranty to cover any issues until either 100,000 miles or 5-6 years, whichever came first. After 4 years of ownership and around 67,000 miles, the truck started experiencing problems with a high idle and then abruptly shutting off. When taken to the dealer, they couldn't replicate the issues during a brief evaluation. However, a week later, while on the way to the bank, to get cash out for are stay at the hospital to give birth to are 6th child the truck shut off and wouldn't start again. The dealer diagnosed the problem as a faulty high-pressure fuel pump due to water in the fuel and tried to charge the author $15,000 for repairs. The author questioned why the diesel fuel water separator and the second fuel filter system on the truck didn't catch the issue earlier and criticized the dealer for their negligence in ensuring safe and reliable transportation.
Truck died and never started again. Metal shavings from fuel pump
The contact owns a 2009 Ford F-350. The contact stated while driving approximately 50-55 MPH, there was a winding sound detected. The code P0088 was displayed. The contact pulled over and the vehicle was towed to the local dealer where it was diagnosed that the fuel pump had failed, causing metal fragments to enter the engine. The vehicle was repaired. The manufacturer was contacted and provided a case number. The failure mileage was approximately 86,000.
CP4 high pressure fuel pump catastrophic failure. My fuel pump grenades and I lost all power on a busy road. I was able to use momentum after the loss of power to safely exit the roadway. I had no warning lamps prior to failure my vehicle will not start now and is currently at a shop being investigated.
First issues is the high pressure fuel pump the cp4. They tend to fall apart sending metal through your injectors all the way back to the fuel tank. It is a well known issue and dodge has made the recall on the same pump. Second is the shaking of the steering wheel after hitting a bump in the road you have to slow down below 25 mph to get it to stop it’s know as “ death wobble”. The other issue is the upper oil pan leaks had it repaired under warranty and less than 2 years later it is leaking again. It is also a well known issue with the 6.7 power stroke diesel motor.
Related recalls
Fuel system, gasoline: delivery
- What is wrong
- Ford is recalling 64,754 my 2008 f-250 and f-350 single rear wheel, 4x4, 156 inch wheel base pick up trucks equipped with a two piece drive shaft for failing to conform to the fuel spillage requirements of federal motor vehicle safety standard no. 301, "fuel system integrity." during a 30 MPH frontal impact into a rigid barrier, the fuel tank can move forward and contact a frame cross member, potentially causing damage to the fuel delivery module which can result in fuel spillage.
- Risk
- Fuel spillage, in the presence of an ignition source, could result in a fire.
- Remedy
- Dealers will install a bracket on the affected vehicles free of charge. The recall began on may 23, 2008. Owners may contact ford at 1‑800‑392‑3673.
Recall number 08V191000 · Recall details
Fuel system, gasoline: storage: tank assembly: filler pipe and cap
- What is wrong
- Vehicle description: f-super duty crew cab pickup trucks (f-350 short wheelbase trucks equipped with a 6 3/4' pickup box and dual rear wheels) were built after a change was implemented to delete a clamp, and later a bracket that provided a ground for the fuel filler pipe. The pickup box may not have been properly grounded.
- Risk
- Without proper grounding, an electrostatic discharge could result during fuel fill up, potentially leading to a fire.
- Remedy
- Dealers will install a fuel filler pipe ground. Owner notification began march 26, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact ford at 1‑800‑392‑3673.
Recall number 01V106000 · Recall details
Fuel system, gasoline: storage: tank assembly
- What is wrong
- Vehicle description: light duty trucks and cab chassis equipped with gasoline engines and dual fuel tanks. The carbon steel fuel pressure regulator in the fuel system can wear out during the life of the vehicle. If the fuel pressure regulator malfunctions, it can cause high fuel system pressure, which damages the fuel pump check valve. This allows fuel to be transferred from one tank to the other, possibly overfilling the non-operating tank, resulting in fuel overflow past the filler cap.
- Risk
- Fuel leakage in the presence of an ignition source could result in a vehicle fire.
- Remedy
- Dealers will have a stainless steel fuel pressure regulator installed. Owner notification began july 9, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact ford at 1‑866‑436‑7332. (see previous the federal safety agency recall 93v‑125/ford recall 93s68).
Recall number 00V424000 · Recall details
Fuel system, gasoline: storage: tank assembly
- What is wrong
- Vehicle description: pickup trucks equipped with gasoline engines and 8 foot boxes, may not fully satisfy the requirements of fmvss no. 301, "fuel system integrity." in a 30 MPH frontal barrier crash test, a fuel tank vapor recovery valve separated internally. During the subsequent static rollover test, fuel spillage exceeded the specified rate.
- Risk
- Fuel leakage, in the presence of an ignition source, could result in a fire.
- Remedy
- Dealers will install a stop plate assembly on the vehicle frame to prevent recovery valve contact with a frame crossmember during the impact sequence.
Recall number 99V311000 · Recall details
Fuel system, gasoline: storage: tank assembly
- What is wrong
- Vehicle description: gasoline and diesel engine pickup trucks equipped with 8 foot beds, do not fully satisfy the requirements of fmvss no. 301, "fuel system integrity." the fuel tank front strap isolator may not be properly positioned which could result in the strap cutting the tank during a 30 MPH front barrier test, resulting in fuel spillage.
- Risk
- During the subsequent static rollover test, fuel spillage exceeded the specified rate, increasing the risk of a fire.
- Remedy
- Dealers will reposition the front strap isolator.
Recall number 99V219000 · Recall details
Fuel system, gasoline: storage: tank assembly: mounting
- What is wrong
- Vehicle description: pickup trucks equipped with 6" beds manufactured from january 5, 1998 through june 4, 1999, do not not fully satisfy the post crash test static rollover requirements of fmvss no. 301, "fuel system integrity." contact between the fuel tank and a fuel tank locator bracket during a front barrier impact test resulted in a cut in the tank, resulting in fuel leakage.
- Risk
- Fuel leakage in the presence of an ignition source could result in a fire.
- Remedy
- Dealers will replace the fuel tank locator bracket with a similar bracket whose design has been revised to incorporate more rounded surfaces where contact with the tank occurs.
Recall number 99V093002 · Recall details
Fuel system, gasoline: storage: tank assembly
- What is wrong
- Vehicle description: gasoline and diesel engine pickup trucks equipped with 6" and 8" beds manufactured from january 5, 1998 through march 21, 1999, do not not fully satisfy the post crash test static rollover requirements of fmvss no. 301, "fuel system integrity." six attachment bolts (m12 bolts) may have been damaged during the 30 MPH front barrier test allowing the bolts to shift or become detached, resulting in fuel spillage.
- Risk
- Fuel leakage in the presence of an ignition source could result in a fire.
- Remedy
- Dealers will augment the box-to-chassis attachment by installing box-to-chassis retaining cables.
Recall number 99V093001 · Recall details
Fuel system, gasoline: delivery: hoses, lines/piping, and fittings
- What is wrong
- The steel fuel return tubes that connect the frame fuel return lines with the engine fuel rail can contact the pinch weld flange connecting the dash panel to the floor pan. Continued contact leads to abrasion of the steel fuel return tube and eventually results in a fuel leak.
- Risk
- Abrasion of the steel tube wall that eventually causes a fuel leak may result in a fire, if a source of ignition is present.
- Remedy
- Ford dealers will replace the fuel return tubes with flexible stainless steel braided/teflon tubes. Dealers will also inspect the fuel supply tubes.
Recall number 94V040000 · Recall details
Fuel system, gasoline: storage: tank assembly
- What is wrong
- A malfunctioning check valve within the fuel pump assembly causes a portion of the unused fuel from one tank to be returned to the second tank. When this occurs, the capacity of the second tank can be exceeded, causing fuel spillage.
- Risk
- Spilled fuel can result in a fire when exposed to asource of ignition.
- Remedy
- Replacement of the fuel pressure regulator and installation of redundant check valves.
Recall number 93V125000 · Recall details
Fuel system, gasoline: storage: auxillary tank: selector devices
- What is wrong
- Incorrectly installed fuel line connectors have fuel supply and return lines crossed.
- Risk
- Fuel could be transferred from one tank to the other,possibly resulting in fuel overflow and spillage, in presence of an ignitionsource, a fire could occur.
- Remedy
- Replace fuel line assembly.
Recall number 89V141000 · Recall details
Questions about the Ford F-350 fuel pump
Which Ford F-350 years have fuel pump failure problems?
The model years with the most reports are 2011 (7 complaints), 2008 (6 complaints) and 1999 (5 complaints).
How much does it cost to fix fuel pump failure on the Ford F-350?
Owners who mentioned a price put the repair at about $9,000 (median of 12 complaints that include a dollar amount). Costs vary with mileage, warranty and where the work is done.
VIN decoder
See the problems and recalls for an exact car
Buying a used Ford F-350?
Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.