Engine compartment fires. Ts
The worst 2000 Gillig Low Floor problems
Ranked by number of owner complaints. Mileage and cost come from what owners wrote.
- Electrical1
Problems by type
Tap a problem to see which part fails, at what mileage and in which other years.
- Electrical1
Recalls 10
Exterior lighting: turn signal
- What is wrong
- Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
- Risk
- The reduced visibility of the turn signals may increase the risk of a crash.
- Remedy
- Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1‑510‑264‑5073 or 1‑800‑735‑1500.
Recall number 17V119000 · Recall details
Equipment adaptive/mobility
- What is wrong
- Certain gillig buses equipped with sure-lok wheelchair tie-down securement assemblies. The sprocket teeth of the retractor assembly may be out of alignment causing the load pawl not to fully seat in the sprocket teeth.
- Risk
- In the event of a vehicle crash, the wheelchair may not be adequately secured possibly resulting in injuries.
- Remedy
- Dealers will inspect and replace the wheelchair securement retractors as necessary. The recall began october 8, 2004. Owners should contact gillig at 1‑800‑735‑1500..
Recall number 04V500000 · Recall details
Engine and engine cooling: engine: other fuel types: turbo/supercharger
- What is wrong
- On certain transit buses equipped with detroit diesel series 40 engines, the turbocharger can fail allowing lubricating oil to spill onto the engine.
- Risk
- This can result in a fire in the engine compartment.
- Remedy
- Dealers will inspect and replace the turbocharger to prevent the possibility of an engine compartment fire. Detroit diesel is conducting owner notification and remedy for this campaign. Gillig issued a renotification letter to owners on february 27, 2007. Owners should contact detroit detroit diesel at 313-5923708 or gillig at 510‑785‑1500.
Recall number 04V486000 · Recall details
Electrical system: wiring: front underhood
- What is wrong
- Incorrect assembly of electrical connections and securement in the engine compartment could come loose.
- Risk
- Incorrect assembly could cause electrical shorts, arcing, and fire.
- Remedy
- Dealers will inspect engine compartment wiring for correct cable assembly, fastner torque, and correct wire protection. Owner notification began october 29, 2003. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact gillig at 510‑785‑1500.
Recall number 03V392000 · Recall details
Electrical system
- What is wrong
- On certain 1998-2002 35' and 40' buses and 1999-2002 29' buses, the installation of the air conditioner unit uses bolts along the edge of the housing for attachment. One specific bolt can be too close to the main power cable attachment. Positional tolerance or the use of too long a bolt could cause an electrical short.
- Risk
- An electrical short could lead to component failure or potentially a vehicle fire.
- Remedy
- Customers have been notified to cut the excess length of the air conditioner unit mounting bolt. Owner notification began october 28, 2002. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact gillig 1‑800‑735‑1500.
Recall number 03V055000 · Recall details
Steering: gear box (other than rack and pinion)
- What is wrong
- On certain low floor 29, 35, and 40 foot buses, the steering gear input shaft bolt installed was a 3/8" diameter coarse thread grade 8 fastener instead of the required 7/16" diameter fine thread grade 8 fastener.
- Risk
- In the event of a crash or some other extraordinary shock load on the steering, a loss of steering could occur.
- Remedy
- Dealers will replace the suspect fastener with the correct fastener. Owner notification began august 6, 2002. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact gillig at 1‑510‑785‑1500.
Recall number 02V189000 · Recall details
Structure: body: door
- What is wrong
- On certain transit buses equipped with adhesively bonded aluminum bus door panels, due to an imperfect bonding of the door panel skin to the panel frame, environmental moisture may infiltrate regions of imperfect bonding and cause separation of the frame and door panel.
- Risk
- Under these conditions, if the panel is separating or has separated, a passenger could fall from the bus onto the roadway, possibly resulting in personal injury or death.
- Remedy
- Vapor will notify customers to have their buses inspected and will install mechanical fasteners to attach the skins to the frame elements free of charge. Owners who do not receive the free remedy within a reasonable time should contact vapor corporation at 847‑967‑8300 or vapor at 1510-785-1500.
Recall number 02V059004 · Recall details
Electrical system: 12v/24v/48v battery
- What is wrong
- On certain transit buses equipped with vanner 60 series battery equalizers, the equalizer could fail to operate properly and cause malfunction of the battery charging system.
- Risk
- Without fusing, the equalizer may melt, burn, or smoke, possibly resulting in a fire or a smoke filled bus, thus necessitating a passenger evacuation of the bus. The failure mode can cause operator distraction, and/or possible personal injury.
- Remedy
- Dealers will inspect the buses for certain equalizers by the date code. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact gillig at 1‑510‑785‑1500 or vanner at 1‑800‑227‑6937.
Recall number 02V071003 · Recall details
Electrical system: 12v/24v/48v battery
- What is wrong
- Vehicle description: transit buses equipped with vanner 60 series battery equalizers. The equalizer could fail to operate properly and cause malfunction of the battery charging system.
- Risk
- Without fusing, the equalizer may melt, burn, or smoke, possibly resulting in a fire or a smoke filled bus, thus necessitating a passenger evacuation of the bus. The failure mode can cause operator distraction, and/or possible personal injury.
- Remedy
- Vanner will notify owners to inspect their buses for certain equalizers by the date code. The affected equalizers will be replaced. Vanner is conducting the owner notification for this campaign and was expected to begin during march 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact vanner at 1‑800‑227‑6937.
Recall number 01V033004 · Recall details
Exterior lighting
- What is wrong
- Vehicle description: low floor transit buses. These vehicles do not comply with the requirements of fmvss no. 108, "lamps, reflective devices, and associated equipment." the reflex reflectors on the side, front (amber) and rear(red) positions are missing.
- Risk
- This is a potential road hazard at night.
- Remedy
- The correct reflex reflectors will be installed.
Recall number 00V145000 · Recall details
See all 10 recalls for the 2000 Gillig Low Floor
Defect investigations
Power cable grounding
In late october 2002, gillig corporation released a field service bulletin advising owners that a protruding bolt on the air conditioning unit (A/C) could make contact with an uninsulated power cable end and possibly cause a fire.the remedy was to remove the excess length from the A/C bolt.as a result of the agency's investigation into this matter, gillig corporation has agreed to conduct a safety recall and notify allowners of the affected vehicles. Based on the manufacturer's safety recall action (03v‑055), this investigation is closed.further use of the agency's resources are unwarranted at this time.
PE03007
Engine compartment insulation sagging
On september 26, 2002, gillig issued a service bulletin (fs-2002-04)addressing the overhead insulation in the engine compartment that over time could sag and contact the hot surface of the engine turbocharger.this type failure could potentially lead to a vehicle fire.due to the agency's investigation into this matter, gillig has agreed to initiate a safety recall campaign and retrofit 2,108 buses with new insulation and retaining strips.the action taken by gillig is sufficient to resolve the issues raised by this investigation.a copy of the safety recall is attached.this investigation is closed.the agency will take further action if warranted by the circumstances.
PE02090
Technical service bulletins for the 2000 Gillig Low Floor 14
Bulletins tell dealers how to fix known problems. A warranty extension means the manufacturer pays for that repair for longer.
- Because of a supply issue with the blue hose covering, Eaton is temporarily making FC-300 hose using black...
- A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
- It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt...
- Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses
- This field service bulletin provides new information from borg warner (DELCO) revising the maintenance...
- This field service bulletin applies to all non-hybrid low floor buses with 480 volt HVAC systems
- This field service bulletin applies to all low floor buses with skf air dryers
- This field service bulletin applies to all low floor buses
- This field service bulletin applies to all low floor buses with aeroquip FC-300 coolant hoses
- This field service bulletin applies to all low floor buses with luminator or twin vision destination signs
What 2000 Gillig Low Floor owners say
Most recent owner complaints, unedited.
Compare the 2000 Gillig Low Floor
Other model years
Questions about the 2000 Gillig Low Floor
Is the 2000 Gillig Low Floor reliable?
Owners have filed 1 complaint about the 2000 Gillig Low Floor, close to a typical Low Floor model year.
What is the most common problem with the 2000 Gillig Low Floor?
Electrical system, with 1 complaint.
How many recalls does the 2000 Gillig Low Floor have?
10 recalls, covering exterior lighting, equipment adaptive/mobility and engine and engine cooling.
Was there a recall on the 2000 Gillig Low Floor electrical?
Yes, 4 recalls: 03V392000, 03V055000, 02V071003. Check your VIN to see if your car still needs the free repair.