The worst 2004 Gillig Low Floor problems
Ranked by number of owner complaints. Mileage and cost come from what owners wrote.
Problems by type
Tap a problem to see which part fails, at what mileage and in which other years.
Recalls 8
Exterior lighting: turn signal: flasher unit
- What is wrong
- Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
- Risk
- The reduced visibility of the turn signals can increase the risk of a crash.
- Remedy
- Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1‑510‑264‑5073 or 1‑800‑735‑1500.
Recall number 18V418000 · Recall details
Exterior lighting: turn signal
- What is wrong
- Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
- Risk
- The reduced visibility of the turn signals may increase the risk of a crash.
- Remedy
- Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1‑510‑264‑5073 or 1‑800‑735‑1500.
Recall number 17V119000 · Recall details
Interior lighting
- What is wrong
- Gillig corporation is recalling certain model year 2001 through 2009 transit buses manufactured between january 2001 and september 2009 equipped with luminator horizon LED side destination signs. The connector board can corrode due to an accumulation of moisture under the connector.
- Risk
- A short could occur, possibly causing smoke and fire.
- Remedy
- Gillig will notify owners and luminator will repair the buses free of charge. The safety recall began on spetember 29, 2009. Owners may contact luminator at 1‑972‑516‑3033 or gillig field services at 1‑800‑735‑1500.
Recall number 09V368000 · Recall details
Fuel system, diesel
- What is wrong
- On certain transit buses built with cummins isl and isc diesel engines equipped with the cm850 fuel system, the engine high pressure fuel lines, from the engine high pressure pump to the engine fuel rail, are prone to failure.
- Risk
- Failure of the line introduces high pressure fuel spray into the engine compartment which can ignite when it comes in contact with a hot surface.
- Remedy
- Cummins will install a fuel line bracket to reduce fuel line stress. A new fuel line will be installed when adding the bracket (please see 06e037). Gillig notified customers on november 22, 2006. Customers may contact cummins at 1‑800‑343‑7357 or gillig at 510‑264‑5031.
Recall number 06V427000 · Recall details
Engine and engine cooling: engine: diesel
- What is wrong
- On certain transit buses manufactured with detroit diesel series 50 engines, the electronic control module (ECM) will need to be reprogrammed to activate the exhaust temperature sensor.
- Risk
- Engine malfunction could possible lead to engine and vehicle damage and potential for a vehicle fire.
- Remedy
- Gillig is working with detroit diesel to reprogram the engines. Gillig issued a renotification letter to owners on february 27, 2007. Owners may contact detroit diesel at 1‑313‑592‑5791 or gillig at 1‑510‑785‑1500.
Recall number 05V473000 · Recall details
Steering: linkages: tie rod assembly
- What is wrong
- On some buses, certain tie rod clamps installed on tie rod assemblies could fail and lead to a steering malfunction.
- Risk
- If both clamps were to fail and the cross tube start to unscrew, significant vehicle misalignment would evolve with the potential for the tie rod end to separate from the cross tube, resulting in loss of steering control and possibly resulting in a vehicle crash.
- Remedy
- Arvin-meritor will notify gillig customers and conduct the remedy at no charge to the customer. Owners should contact arvin-meritor at 1‑248‑435‑1000 or gillig at 1‑510‑785‑1500.
Recall number 04V610000 · Recall details
Engine and engine cooling: engine: diesel
- What is wrong
- On certain phantom and low floor transit buses equipped with cummins 8.3l and 8.9l isc and isl diesel engines, oil can leak into the engine compartment from a crack in the cup plug.
- Risk
- Oil leakage on a hot engine can result in an engine compartment fire, possibly resulting in injuries.
- Remedy
- Cummins will conduct the owner notification and remedy for this campaign. Cummins will isntall a steel cup plug boss cap on the affected engines. Owners should contact cummins customer assistance center at 1‑800‑343‑7357 or gillig at 510‑785‑1500.
Recall number 04V485000 · Recall details
Fuel system, other
- What is wrong
- Certain low floor buses powered by a gaseous hydrogen fuel system. These transducers were made of 17-4 ph stainless steel material which may be susceptible to embrittlement in a high-pressure hydrogen application environment.
- Risk
- Embrittlement could potentially lead to a transducer diaphragm failure.
- Remedy
- Dealers will replace the transducer. The recall began july 12, 2004. Owners should contact gillig at 1‑510‑785‑1500.
Recall number 04V308000 · Recall details
Technical service bulletins for the 2004 Gillig Low Floor 14
Bulletins tell dealers how to fix known problems. A warranty extension means the manufacturer pays for that repair for longer.
- Because of a supply issue with the blue hose covering, Eaton is temporarily making FC-300 hose using black...
- A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
- It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt...
- Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses
- This field service bulletin provides new information from borg warner (DELCO) revising the maintenance...
- This field service bulletin applies to all non-hybrid low floor buses with 480 volt HVAC systems
- This field service bulletin applies to all low floor buses with skf air dryers
- This field service bulletin applies to all low floor buses
- This field service bulletin applies to all low floor buses with aeroquip FC-300 coolant hoses
- This field service bulletin applies to all low floor buses with luminator or twin vision destination signs
Compare the 2004 Gillig Low Floor
Other model years
Questions about the 2004 Gillig Low Floor
Is the 2004 Gillig Low Floor reliable?
Owners have filed 0 complaints about the 2004 Gillig Low Floor.
What is the most common problem with the 2004 Gillig Low Floor?
There are not enough complaints to tell.
How many recalls does the 2004 Gillig Low Floor have?
8 recalls, covering exterior lighting, interior lighting and fuel system, diesel.
VIN decoder
See the problems and recalls for an exact car
Buying a used 2004 Gillig Low Floor?
Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.
Check its history