Fuel rail leak at the crossover pipe, getting fuel on valve covers, and close to exhaust manifold. Fuel leak will not stop. Contacted chrysler dealership, no known fix available. Fuel rail discontinued, no parts available. No known recall available. Potential fire hazard!!
Plymouth Grand Voyager fuel leak problems
66 of the 2,395 owner complaints about the Plymouth Grand Voyager describe fuel leak, most of them for the 1996 model year.
- owner complaints
- 66
- worst model year
- 1996
- typical mileage
- 141,000
By model year
Often reported together
Fuel smell 15Wipers 3Fuel pump 3Fuel gauge 2Check engine light 2Stalling 1Jerking 1
What owners say
Tl* the contact owns a 1997 plymouth grand voyager. The contact noticed an extensive fuel leak coming from the vehicle. The contact was not notified of the federal safety agency campaign number: 00v268000 (fuel system, gasoline). The vehicle was towed to the contact's residence due to the failure. The manufacturer was notified of the failure. The approximate failure mileage was 196,559.
Takata recall,serpentine belt has shredded at least six times and just came off three times ,tensioner replaced three times,idler pulley twice,when belt shreds wires sever and van stops abruptly,windshield wipers stop abruptly hesitating before resuming,sway bar links need replaced,o2sensors check engine light to come on,cv axles failing replaced right twice,hub assembly and brake calipers miss aligned,engine mounts failed and needed,replaced,airbag and ABS lights on dashboard panel fuse blowing,taillights possible short causing brake light to fail,battery needing to be disconnected. To save battery from dyeing due to brake lights staying on constantly, transmission jerking and hesitating in reverse and first gear,passenger side window not operating possible problem,back windows open but will not always shut,horn not working,replaced fuel pump due to gas leak,when braking van lurches forward,front end shakes, tie bar ends replaced,heater blows cold on passenger side and not cooling,most problems occurred while driving,replaced stop brake switch, brake light drivers side illuminated, but not when brake petal pushed,transmission leaking by cv axel,turn signals and panels inside by dash not always operating,only when negative terminal is readjustment,lights flashing as if panic mode was activated when car is not on,rattling. Sound from front of van possible cv axel or suspension.
Tl* the contact owns a 1991 plymouth grand voyager le. The contact stated that there was a leak in the fuel rail. The vehicle was taken to a local mechanic for routine maintenance where they discovered the fuel leak. The manufacturer was notified of the failure who advised that the vehicle was too old for them to provide any assistance. The failure mileage was 155,000.
1996 plymouth grand voyager had an engine fire due to a leaking fuel rail - investigation revealed the rail was under an open recall that was never fixed and I never received notice of it.
Purchased vehicle used a year ago, after 1 fuel fill up service engine light came on and smelled fuel strongly in the back. Noticed raw fuel leaking onto the left rear tire& wheel well. Took to dealer for tests, they found leaks from ldp to the tank at a rubber elbow with a raw fuel leak at the connection between the filler neck and rollover valve. Told we need fuel tank replaced to fix the problem costing more than $700!
My 1996 plymouth grand voyager mini-van 3.3 liter v6 2 wheel drive broke down. Apparently in the transport, loading, or unloading of the vehicle on my trailer, one of the muffler mounts became disconnected and the other muffler mount the bolt into the frame was pulled out. This caused the muffler and exhause to shift. I did not notice this prior to operation of the vehicle after performing the initial repairs that caused the breakdown (water pump / serpentine belt failures). The shift of the muffler caused my fuel line and gas tank to melt and devoloped leaks. The level in the gas tank was low enough that no gas was leaking; however, the fuel line was spraying gasoline on the underside of the vehicle and on the hot muffler. I consider myself fortunate that I did not have a fire in the event. I have yet to repair either of these leaks, and I intent to take photos prior to repairs. I did have to move the muffler to find the leaks, and that is the only work I have done at this time and I will not be driving the vehicle until the leaks are repaired. This could be applicable to other grand voyagers that pass over a large objects that could strike the muffler (I.e rocks, curbs, etc.)
While the vehicle was idling consumer smelled a strong gasoline odor. Consumer opened the engine compartment, and observed gas dripping from the fuel rail. Vehicle was immediately parked, and the manufacturer was informed.*ak
This van has had the fuel rail leak recall done to it however it has now developed a leak under their fix. Their fix does not work - I have fuel running out over the top of the engine, valve cover and onto the exhaust. I found this on the recall web site: the fuel injection delivery system can leak fuel from some of the sealing o-rings or from hair line cracks in the thermostat fuel injection rail. Fuel leakage in the presence of an ignition source can result in a fire. 1,163,000 vehicles are affected by this recall. Dealers will install a seal on the vehicle fuel rails to prevent external leakage of fuel from the fuel rail crossover tube, should the existing o-rings continue to degrade. Their fix does not work, I took great detailed pictures to show your engineers. I just dropped off the van to get fixed, however their recall fix does not work. I am going to demand that they replace everything.
The fuel rail located on the fuel injection system was leaking gas onto the engine manifold, resulting in a fire. The fire was extinguished by consumer.
Related recalls
Fuel system, gasoline: fuel injection system
- What is wrong
- Vehicle description: mini vans built with 3.3l and 3.8l engines have fuel rails with nitrole rubber o-ring seals that can degrade over time. Fuel leakage from the underhood fuel injection fuel rail could result, increasing the likelihood of a vehicle fire.
- Risk
- Fuel leakage in the presence of an ignition source can result in a fire.
- Remedy
- Dealers will install a seal on the vehicle fuel rails to prevent external leakage of fuel from the fuel rail crossover tube, should the existing o-rings continue to degrade. Owner notification began on january 25, 2002. Due to the large quantity of vehicles involved in this campaign, the owner notification will be phased over the next several months. However, if a vehicle is leaking fuel from the o-rings, the vehicle should be taken into a dealer to have this repaired as soon as possible. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact daimlerchrysler at 1‑800‑853‑1403.
Recall number 00V268000 · Recall details
Fuel system, gasoline: delivery: fuel pump
- What is wrong
- Vehicle description: minivans. Fuel can leak from the fuel tank at the interface of the fuel pump module attachment.
- Risk
- If a fuel leak occurs in the presence of an ignition source, a fire could occur.
- Remedy
- Dealers will replace the fuel pump module attaching nut with a nut that includes tighter design tolerances. The sealing o-ring will also be replaced.
Recall number 99V216000 · Recall details
Fuel system, gasoline: storage: tank assembly: filler pipe and cap
- What is wrong
- A static electric charge can build up on the ungrounded metal section of the fuel filler tube.
- Risk
- This condition could cause a spark to occur when fueling the vehicle and possibly ignite the fuel vapors.
- Remedy
- Dealers will install a ground strap for the fuel filler tube.
Recall number 96V002000 · Recall details
Fuel system, gasoline: delivery: hoses, lines/piping, and fittings
- What is wrong
- The fuel tank rollover valve can allow fuel to pass into the vapor canister resulting in the potential for fuel leakage.
- Risk
- Fuel leakage increases the potential for a vehicle fire.
- Remedy
- Dealers will replace the fuel tank filler tube with a filler tube that has an additional rollover valve. The associated rollover valve vapor hoses will be rerouted.
Recall number 95V236000 · Recall details
Questions about the Plymouth Grand Voyager fuel leak
Which Plymouth Grand Voyager years have fuel leak problems?
The model years with the most reports are 1996 (34 complaints), 1997 (10 complaints) and 1993 (7 complaints).
VIN decoder
See the problems and recalls for an exact car
Buying a used Plymouth Grand Voyager?
Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.
Check its history