February 13, 2026 Service bulletin

After the charging process is complete, an instrument cluster message with a charging error appears and FC...

Mercedes-Benz technical service bulletin LI47.70-P-076030 for 2020-2026 Mercedes-Benz GLB 250, 2022-2025 Mercedes-Benz Eqb 300 4matic and 2023-2025 Mercedes-Benz EQB 250+ and others.

Bulletin number
LI47.70-P-076030
Component
Electrical system
Summary
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For the plug-in hybrid model series 118, 167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"

Owners of these vehicles have filed 147 complaints in the electrical category.