Filed Jun 24, 2002 · Fuel system · WA

Gas tank is pumping gas to front/back of vehicle. Also, leaking onto the ground, and causing vehicle not to get any gas. Cause unknown. Dealer notified.

Filed May 23, 2002 · Fuel system · MN

Consumer states that due to a malfunctioning check valve, the gas tank is leaking fuel. Please give any further details.

Filed Apr 23, 2002 · Electrical, Fuel system · CA

Have been to ford dealer for two recalls, ignition and fuel regulator. No charge to me. Gas is still coming out of the filler neck of the tank "I am not using, I switch to that tank and gas comes out of the other tank--that I am not using. The dealer says this is not a recall and I need to pay for new fuel pumps in each tank. I don't understand that since the truck is getting gas fine, just to much and being returned to the wrong tank. Not being returned to the tank that is being used. I feel that this should be a recall and should not cost me $1000.00. Hope someone can help me.

Filed Mar 29, 2002 · Fuel system · MN

After having recall 89v1141000 serviced, one week later, problem came back worse than before. Fuel was still flowing from one tank to the other. Dealer was aware of problem, but could not solve it.

Filed Feb 24, 2002 · Fuel system · MS · fire

2 recalls have been completed on this fuel transfer problem and dealer answer was they just put on parts and didn't expect it to fix problem!

Filed Feb 4, 2002 · Fuel system · CO

Front gas tank pumps gas to rear tank, causing it to overflow.

Filed Nov 8, 2001 · Fuel system · AL

Consumer had recall 93v125000 repairs done in august 2001, and within in 2 weeks fuel started leaking again. Vehicle has dual tanks. First time front tank was drained to stop overflow. Second time taken to service technician to put another fuel regulator to control fuel flow. Consumet was taken vehicle into repairs shop for thid time, and was not sure if this could be rectified.

Filed Aug 29, 2001 · Fuel system · NJ

When filling both gas tanks, fuel by passing to one tank causes an overflow condition which results in fuel leakage. Also, there is a very strong gas odor in passenger's compartment. Dealer has been contacted.

Filed Aug 28, 2001 · Fuel system · GA

Received recall 93e039000. Contacted dealership, and had fuel tank switch repaired. However, remedy failed. Contacted dealer, and mechanic wanted to charge consumer for replacement of fuel pumps on both tanks.*ak consumer states he had already paid for the replacement of the fuel tank and selector switch, he found out about the recall and took the vehicle to the dealer, they replaced it again and charged the manufacturer for parts even though consumer had already had them replaced, the problem is still occurring and dealer stated consumer needed to replace both fuel pumps at 1150 dollars, consumer has had all repairs except the replacement of the front fuel tank made by a napa authorized dealer.

Filed Jul 15, 2001 · Fuel system · OK

My 1990 ford f150 is doing the same exact thing as mentioned in this the federal safety agency campaign #93v125000 but ford sais it's not on their recall list?

Filed May 1, 2001 · Fuel system · TX

A very dangerous condition with my ford f-150 involving the fuel line/gas tank surfaced on 4/27/01 in my attached garage. After the vehicle was stopped in the garage, significant quantities of gasoline were found to be exiting one of the two fuel tank caps on to the floor. Tomball ford replaced the components causing this safety hazard in jan 1996 under ford recall 93s68. It is obvious the recall did not work.!! These facts have been verified by cillis car care, 13650 schroeder rd, houston, tx 77070. According to tomball ford, they say they are not obligated to once again repair the components of the fuel system on this vehicle. I demand that the d.o.t. Act on this situation immediately. My truck should be repaired correctly at no cost to me. Further, for the safety of the public, ford should be required to conduct another recall and perform recall 93s68 properly!!!!!

Filed Apr 27, 2001 · Fuel system · TX

Vehicle t was driving roughly, and consumer smelled gasoline he has dual tank. Truck was fixed on recall 01-jan-96 .

Filed Apr 25, 2001 · Fuel system · AZ

Fuel tank started leaking fuel from one tank to the other causing fuel to over flow and out of tank onto the ground, after two attempts problem was corrected.

Filed Apr 20, 2001 · Fuel system · NH

Fuel from rear tank is tranferring all fuel into front tank until it gets full, then it will leak out of fuel filler, causing fire hazard.

Filed Apr 4, 2001 · Fuel system · OH

Front fuel tank pouring fuel out from several areas.

Filed Feb 27, 2001 · Fuel system · CA

93 v 125 000/fuel tank assembly: vehicle experienced portion of unused fuel from one tank to be returned to second tank. When this occurred, second tank exceeded, causing fuel spillages. Spillage can result in a fire when exposed to a source of ignition; dealer ,and informed that this vehicle not covered under a manufacturer's recall due to VIN.

Filed Dec 13, 2000 · Fuel system · FL

Recall 93v125000/ fuel pump repairs done by ford. However, fuel spillage still happening, problem is caused by fuel pump relay.

Filed Nov 16, 2000 · Brakes, Fuel system · CA

The reason for my complaint is that my truck has a damaged check valve. I have spent my own money to try and fix the problem, yet it still does not work properly. What is happening is I have a daul tank system. When I switch my tank to the rear it pumps gas to the motor but also pumps gas into the front tank causing it to overflow, thus creating a potential fire hazered for my wife and kids. I called ford and they said there is no recal on such a deffect. Yet my mechanice pulled up a document off his computer under the (2000 mitchell repair information co. L.l.c.) under safty recall #93s68 which addresses this very problem. I beleve it is severe enough to bring it to your atten, and am asking you to get ford to fix this defect before my truck goes ablaze.

Filed Oct 10, 2000 · Fuel system · MT

Ea99032;dual fuel tank crossflow/leakage: when rear tank was being used excess fuel was being returned to the front tank. Front tank overfilled, and fuel was pouring onto the ground. Owner was told that this problem was corrected in 1994 under recall # 93v125000 fuel: fuel tank assembly. Owner purchased truck in 1995, and problem existed then. Please provide any further information.

Filed Oct 10, 2000 · Fuel system · PA

Recall 93v125000. Fuel from one tank is being transferred to second tank, causing fuel leakage due to a malfunctioning check valve. A recall has been issued on vehicle's make and model and was done in 1995 but defect has reoccured.

Filed Sep 28, 2000 · Fuel system · CA

After having a recall fixed concerning fuel pressure regulator, fuel pump started to go bad. Dealership has found that rear fuel pump was bad, and front pump was slow.

Filed Aug 22, 2000 · Fuel system · LA

One fuel pump would not allow gauge to switch to front (rear showed full), other pump was not checking off (check valve) and allowed gas to leak out of the rear tank. Nlm

Filed Jul 31, 2000 · Fuel system · FL

Fuel transfers from first tank to the second tank, causing fuel leakage. Please give any further details.

Filed Jul 18, 2000 · Fuel system · VA

A defective fuel check valve causes the fuel to spill onto the 2nd fuel tank which it exceeded and caused a fuel spillage which may result in a fire. There is a recall 93v12500 for this problem. But this vehicle is not affected by this recall due to VIN. *ak

Filed Jul 5, 2000 · Fuel system · MI

Fuel tank leaks fuel when it's full. *ak

Filed Jun 21, 2000 · Fuel system · IL

A malfunctioning check valve within the fuel pump assembly caused a portion of unused fuel from one tank to return to the second tank, resulting in fuel spillage. A recall has been issued on vehicle's make/model. However, this vehicle was not included due to VIN. The manufacturer has been notified.

Filed Jun 9, 2000 · Fuel system · AL

Copper piece on the fuel tank broke, causing a fuel leakage. Manufacturer said they do not make that part any more.

Filed Jun 7, 2000 · Fuel system · CA

Firestone installed a new fuel pump/switch and fuel sensor.

Filed May 18, 2000 · Fuel system · TX

Consumer took vehicle to dealer to repair malfunctioning check valve which caused fuel spillage, while driving home after repair consumer notice fuel was still spilling out of the vehicle, consumer feels vehicle was not really repaired. (93v‑125) nlm

Filed May 4, 2000 · Fuel system · IL

Recall 93v‑125 of the check valve within the fuel pump was repair and failed after repair causing portions of fuel from one tank to be pump to the second tank exceeding the capacity of the second tank resulting in leakage. Yh