Filed May 1, 2000 · Fuel system · OK

When using the rear tank, fuel is being pumped back into the front tank. When front tank is full, fuel being pumped from the rear tank goes into the front tank which causes the front tank to overflow. Recall issued for this problem, but this vehicle not included due to VIN. *ak

Filed Apr 26, 2000 · Fuel system · CA

A malfunctioning check valve allows fuel from one tank to transfer to second tank, causing fuel leakage. Vehicle is not included in recall 93v125000 due to VIN. Please give any further details.

Filed Mar 22, 2000 · Fuel system · FL

A portion of the unused fuel from one tank to be returned to the second tank. The capacity of the second tank can be exceeded, causing fuel spillage. Dealer has been contacted. Please provide futher information.

Filed Feb 9, 2000 · Fuel system · TX

Check valve within the fuel pump assembly failed prior to recall notice causing a portion of the unused fuel from one tank to be returned to the second tank. When this occurs the capacity is exceeded causing fuell spillage. Fuel leak has caused paint and molding damage. Nlm

Filed Feb 8, 2000 · Fuel system · AZ

Ea99023;dual fuel tank cross/flow.leakage; fuel pumps from the rear tank into the front tank, causing fuel spillage when both tanks are filled and the pump is turned on. Prolbem was reported to the dealership. The problem was not corrected.

Filed Feb 8, 2000 · Fuel system · AZ

Fuel pump failed causing fuel to leak from the tank when the pressure builds up. Nlm

Filed Feb 4, 2000 · Fuel system · CA

Vehicle has dual tanks, and front tank travels though the rear tank. If both tanks are fuel, rear one will spill out faster. If one tank is empty and other tank is full, the other gas tank will leak because the gas will come out quicker.

Filed Feb 1, 2000 · Fuel system · VA

A malfunctioning check valvue in the fuel pump assembly causes a portion of unused fuel from one tank to be returned to the second tank, resulting in fuel spillage. A recall has been issued on the make/model. However ,this vehicle was not included due to the VIN. Dealer and manufacturer have been notified.

Filed Dec 21, 1999 · Fuel system · VA

When both tanks are full and when frontal tank gets low on fuel, rear tank drains off fuel from the rear to the frontal tank. Consumer has yet to contact the dealer. Please provide any further details.

Filed Dec 21, 1999 · Fuel system · WI

I am an otr truck driver and I am very aware of problems with all vehicles that I drive. I came back to my work terminal and noticed a very strong smell of gasoline coming from my truck. I looked under it and saw that the rear fuel tank was leaking quite obviously from the seam. I contacted my local dealership and asked if there was a recall on the fuel tank, he said no. I then was told to contact ford and I asked if they had a recall on this vehicle and they said that the vehicle had been through a recall fix back in 1993. I hardly think that a fuel tank that was repaired would start leaking 6 years later, especially from the seam on the tank. I was told that my bumper to bumper warranty was up and that ford would not take care of my problem. Dear sirs, I have two children and a wife who depend on me to provide the best care and protection. How can I protect my family from companies that don't care about anyone and only care about their pocketbook.

Filed Dec 8, 1999 · Fuel system · PA

Dual fuel tanks are defective, allowing one to overflow into the other and spill gas out of the vehicle. Dealer has repaired under recall before. Problem exists currently.

Filed Dec 7, 1999 · Fuel system · TX

Ford will not aknowledge recall information concerning fuel tank auxiliary selector and switch failure. Recall 89v141000.

Filed Nov 3, 1999 · Fuel system · IL

A portion of the unused fuel from one tank is returning to the second tank, resulting in fuel spillage . The vehicle has been repaired under recall prior to this incident. The dealer and manufacturer have been notified.

Filed Aug 23, 1999 · Fuel system · SC

Ford has a recall on this but apparently where this truck was built, it is not included in this recall, campaign # 93v125000. How can they recall over a million trucks, knowing that there is a problem with this part and not include a truck that is having the same problem.

Filed Jul 26, 1999 · Fuel system · DE

Vehicle was reapaired under recall#93v125 in 1995. A portion af the unused fuel is going to the other tank, resulting in fuel leakage. The dealer has repaired the vehicle twice since the recall was done . The manufacturer has been notified.

Filed Jun 14, 1999 · Fuel system · IL

Fuel is returning to the wrong tank which is causing an overflow and resulting into a spillage. This is the second time vehicle has been into repair shop for spillage problem.

Filed Jun 2, 1999 · Fuel system · WA

Recall repair completed on fuel switch (89v‑141) however failed causing gas to flow from vehicle. Mjs

Filed Apr 26, 1999 · Fuel system · WA

Since october 98 consumer's been experiencing fuel leakage out of the dual tanks . Consumer got out of vehicle and stepped into a puddle of gasoline.

Filed Mar 12, 1999 · Fuel system · TX

Recall # 93v125000 fuel: fuel tank assembly - problem with fuel tank continues even though recall work was performed over 9 months ago. The dealer wants to charge owner to have fuel pumps replaced. Owner feels recall work was never performed or the parts used were defective.

Filed Mar 9, 1999 · Acceleration, Body · OR

1990 f150 already involved in recall for "faulty check valve causing fuel leaks" other 1990 model trucks were involved in the "stuck throttle linkage". Both of these are safety issues. The third problem is both power door locks failed at about the same time.

Filed Feb 26, 1999 · Fuel system · NC

Recall 93v125000/93s68; vehicle was fixed for recall in aug 11,1994, but the defect reoccurred for same problem. Consumer claims corrective action not correctng defect, and wants to be reimbursed for repairs. *ak

Filed Jan 27, 1999 · Fuel system · LA

The dual fuel tanks are pushing the gasoline from one tank to the other, which is causing them to overflow and leak. Dealer says the pump needs to be replaced.

Filed Jan 7, 1999 · Fuel system · VA

Consumer received a recall for the fuel tank assembly. Manufacturer recall #93s68, the federal safety agency recall #93v125000. Consumer had this recall taken care off, but it has failed again. Consumer would like the dealer to fix it again at no expense. Dealer has been contacted and refuses to do this.

Filed Jan 6, 1999 · Fuel system · AR

Intermittently, when on long trips, fuel in the rear tank becomes much higher than in the front tank. This causes pressure to build up and fuel sprays out of the rear tank filler port. A quarter to a half of a tank of fuel can be lost. This is a serious fire hazard. Ford claims to have no idea what could be causing the problem.

Filed Jan 6, 1999 · Fuel system · AR

Fuel in rea rtank becomes much higher than in the front tank, pressure builds up, and fuel spills out of rear tank. Can easily lose 1/4 to 1/2 tank of fuel.

Filed Jan 6, 1999 · Fuel system · AR

Intermittently, when on long trips, fuel in the rear tank becomes much higher than in the front tank. This causes pressure to build up and fuel sprays out of the rear tank filler port. A quarter to a half of a tank of fuel can be lost. This is a serious fire hazard. Ford claims to have no idea what could be causing the problem.

Filed Nov 24, 1998 · Fuel system · MN

Invest#rq98008; duel fuel tanks overflow to other tank ,causing fuel to leak.

Filed Nov 20, 1998 · Fuel system · KY

The consumer has been experiencing problems with fuel tank assembly. Fuel check valves malfunctioned, causing gas to transfer from tank to tank. The defects described comply with recall 93v125000.

Filed Nov 4, 1998 · Fuel system · MO

Vehicle factory equipped with a fuel injection system with 2 fuel tanks. When switched to used rear tank, the unused portion of the fuel pumped from the rear tank into the front tank. If the fuel fron the front tank is not used first, the tank over flows. This vehicle was subject of recall in 1993, but problem was not corrected. Dealer will only make repairs at owner's expense. *ak

Filed Sep 28, 1998 · Fuel system · AZ

Consumer complained of remedy failure of the federal safety agency recall # 93v‑125. Four year later vehcle still experiences malfunctioning of check valve within the fuel pump assembly, causing a portion of unused fuel from one tank to be returned to second tank, when it occurs, the capacity of second tank can cause fuel spillage. Manufacturer notified.