Vehicle recall on fuel pressure regulator and check valves, however dealer denies recall bulletin.
1990 Ford F-150 fuel system complaints
Page 5 of 6: complaints 101 to 130 of 147, newest first, as owners wrote them.
Intermittently the fuel in the rear tank leaks out of the fuel tank. Owner has notified the dealer and the manufacturer .
Vehicle was repaired under fuel tank recall in 93. The fuel from one tank shifts to the second tank, causing fuel leakage. The dealer will correct problem at owner expense.
Extensive squealing at all speeds before and after driveshaft problem. Serious vibration coming from transfer case/transmisssion at high speeds.
Fuel pump check valve recall repair does not solve the problem.
There is a malfunction within the check valve, causing a portion of unused fuel from one tank to be returned to second tank, resulting in a fuel leakage. Also, there is a recall for listed problem 98v125000. Vehicle not included. *ak recall number is 93v125.
After having recall repair work done on fuel tank, fuel in one tank is flowing to the second tank, causing fuel spillage. Recall # 93v125000.
There was a recall listed on this vehicle for the fuel tank. Dealer said that they corrected the problem, but the owner is still having the same problem. The fuel was transferred from one tank to another, causing overflow in the tank, resulting in spillage of the fuel. This could start a fire. Owner knew that if this defect was corrected it was not corrected properly. What should be the next step in the process since the recall was suppose to have been corrected? Recall number is (89v‑141).
Rear fuel tank assembly transmits fuel to front tank. No prognosis has been established to eliminate instability.
When switching from one tank(auxiliary)to another, there is a spillage of fuel from the filler tube. The problem has not been corrected.
Vehicle's fuel pressure regulator was on recall, consumer went to have recall work done, records showed they had already been repaired when they had not. The part failed causing fuel to pour out of tank when full.
After having recall work done on fuel tank, fuel is flowing from one tank to the second, causing fuel spillage. Recall # 93v125000.
Check valves in the fuel pump failed.
The rear gas tank overfills the front one, and causes gas to spill out onto the ground. *ak the malfunctioning check valve within the fuel pump assembly was causing the tank to over fill and spill the fuel.
Fuel tank failure. Fuel is going from one tank to the another tank, causing tank to become filled and fuel is spilling out of tank. Repaired about (3) or (4) years ago for same problem. Vehicle is at dealership for same problem now.
Rear gas tank leaked twice.
The vehicle was serviced under recall 93v125000 and the same problem still occurs. The tank still leaks and overflows.
Owner states that his vehicle has dual fuel tanks, the problem is that when one tank is full it causes the other tank to push fuel out the filler tube, owner is concerned for his safety because gas runs down the side of vehicle.
Auxillary selector switch failed, allowing fuel from front tank to spill over into rear tank/onto garage floor.
Dual fuel tanks: the rear tank is pumping gas into the front tank until it spills out. This vehicle was repaired for this problem about one year ago.
Recall related 93v125000, malfunctioning of the check valve assembly, in for repair when front tank filled up and the rear tank lost all the fuel.
Vehicle taken to dealer on (3) separate times. Dealer did not correct problem. Vehicle taken to another dealership. Problem was corrected.
Has received recall notice several months ago, dealer still has not received patrts to fix problem.
Fuel pump in rear tank pumps fuel into front tank.
Fuel transfers from front tank to rear tank, causing an overflow.
Repaired under the recall and now the consumer is still having problems with the fuel pump presure. Please describe in detail.
Replced exhaust manifold three times; also, replaced intake manifold/ oil pan gasket/rear main seal.
Gas from front tank spilled over into rear tank.
When vehicle was returned from having recall repairs, 93v125, consumer noticed problem was still occurring, unused fuel is not returned to same tank, this results in tank overtopping and fuel spilling, consumer returned to dealer who refused to do additional repairs, vehicle still has not been repaired.
Fuel tank auxiliary selector/switch failed, resulting in fuel expulsion prior to recall (93v‑125).