Check a VIN

February 5, 2026 Service bulletin

After the charging process is complete, an instrument cluster message with a charging error appears and FC...

Mercedes-Benz technical service bulletin LI47.70-P-076030 for 2020-2026 Mercedes-Benz CLA250, 2020-2026 Mercedes-Benz GLB 250 and 2022-2025 Mercedes-Benz Eqb 300 4matic and others.

Bulletin number
LI47.70-P-076030
Component
Electrical system
Summary
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The instrument cluster message and the FC memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For model series 206 and 223 with code 802: Perform a software update and SCN coding for the control unit "N83/11 - AC charger for high-voltage battery (SGLG)" in order to remedy the problem. For model series 243: The correction is already available. Perform a software update and SCN coding for the control units "N116/5 - Direct current charging connection unit (DCCU)" and "N83/11 - AC charger for high-voltage battery (SG-LG)" in order to remedy the problem.

Owners of these vehicles have filed 157 complaints in the electrical category.

Vehicles covered

VIN decoder

See the problems and recalls for an exact car

Buying a used Mercedes-Benz CLA250?

Check the exact car before you pay: accidents, salvage or flood titles, odometer readings and previous owners.

Check its history